Celgene Corporation
556 Morris Ave, Summit, New Jersey, United States
FEI 3004991673DUNS 080392427
Company: Bristol Myers Squibb Company · Linked by exact D-U-N-S match (102826703) in FDA registration data
FDA has 15 inspections on file for Celgene Corporation in Summit, New Jersey (FEI 3004991673), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued. Two of the seven FOIA requests for this site have asked FDA for this inspection's 483.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, API manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Bristol Myers Squibb Company (D-U-N-S 102826703), has registered 7 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 15, 2009–2025
- 0 OAI · 6 VAI · 9 NAI
- Inspections with 483 observations shown
- 4 of 15
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 7 requests, latest Apr 1, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
15 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene TherapiesCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch Monitoring4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 505-1(f)(3)(A)
Failure to comply with REMS Elements to Assure Safe Use (ETASU) A
An application holder did not make training available to prescribing healthcare providers (HCPs), as required by your approved REMS Element to Assure Safe Use (ETASU) A.
- FDCA 505-1(f)(4)
Failure to comply with REMS Implementation System
An application holder did not comply with the audit plan and schedule described in the REMS, as required by your approved REMS Implementation System.
- FDCA 505-1(f)(3)(E)
Failure to comply with REMS Elements to Assure Safe Use (ETASU) E
An application holder did not instruct healthcare providers or health care facilities to monitor patients after administration of the drug, as required by your approved REMS Element to Assure Safe Use (ETASU) E.
- FDCA 505-1(f)(3)(B)
Failure to comply with REMS Elements to Assure Safe Use (ETASU) B
An application holder did not ensure mechanisms are in place that allow pharmacies the ability to complete the certification process, as required by your approved REMS Element to Assure Safe Use (ETASU) B.
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Mfg / Processing Operations Area
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- NAINo objectionable conditions that need follow-upBiologics · Bioresearch MonitoringNone
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
Acceptance criteria for sampling & testing
Acceptance criteria for the sampling and testing conducted by the quality control unit is not adequate to assure that batches of drug products meet each appropriate specification as a condition for their approval and release.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Procedure Deviations Recorded and Justified
Deviations from written production and process control procedures are not justified.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Bioresearch Monitoring6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Failure to develop written procedures
Written procedures have not been developed for the surveillance, receipt, and evaluation of post marketing adverse drug experiences.
Failure to review ADE information
Adverse drug experience information obtained or otherwise received from any source was not promptly reviewed, including information from post marketing clinical investigations.
Late submission of quarterly safety reports
Not all quarterly periodic adverse drug experience reports have been submitted within 30 days of the close of the quarter.
Late submission of 15-day report
Not all adverse drug experiences that are both serious and unexpected have been reported to FDA within 15 calendar days of initial receipt of the information.
Failure to separately submit original and follow-up reports
Initial post marketing 15-day Alert reports and follow-up reports have not been submitted under separate cover.
Show 1 more citation
Failure to report non-alert ADEs
Individual ADEs which were not reported to FDA in a post marketing 15-day alert have not been included in a periodic safety report.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Seven requests to FDA under the Freedom of Information Act named this site, most recently on Apr 1, 2026. Each one asked for a Form 483.
Inspection ending Jul 18, 2025VAI
2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Apr 3, 2026. FDAgent holds no copy that FDA posted.
- Apr 1, 2026FDA-FOIA-2026-3141Form 483Records released
- Sep 22, 2025FDA-FOIA-2025-11136Form 483· 1 of 5 sitesRecords released
Inspection ending Dec 6, 2024VAI
2 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Feb 24, 2025FDA-FOIA-2025-1701Form 483 + EIRWithdrawn
- Feb 19, 2025FDA-FOIA-2025-1570Form 483· 1 of 4 sitesClosed
Inspection ending Jun 16, 2023VAI
3 requests. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Oct 23, 2024FDA-FOIA-2024-9396Form 483· 1 of 3 sitesClosed
- Nov 28, 2023FDA-FOIA-2023-10620Form 483Closed
- Nov 21, 2023FDA-FOIA-2023-10445Form 483Closed
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 15 inspections, with how many of them cited each.
- 21 CFR 211.100Written procedures; deviations2 of 4
- 21 CFR 211.22Responsibilities of quality control unit1 of 4
- 21 CFR 211.42Design and construction features1 of 4
- 21 CFR 211.137Expiration dating1 of 4
- 21 CFR 211.165Testing and release for distribution1 of 4
- 21 CFR 211.180General requirements1 of 4
- 21 CFR 314.80Postmarketing reporting of adverse drug experiences1 of 4
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, API manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Bristol Myers Squibb CompanyD-U-N-S 102826703
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Bristol Myers Squibb Company (D-U-N-S 102826703) as the registrant for this site and the 7 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Bristol-Myers Squibb Holdings Pharma, Ltd. Liability CompanyManati, Puerto Rico · FEI 265008912 inspections12latestJul 12, 2021VAI1 warning letter, Sep 30, 2010
- Bristol-Myers Squibb CompanyDevens, Massachusetts · FEI 30084550695 inspections5latestJul 8, 2025VAINone on file
- Swords Laboratories Unlimited CompanyMulhuddart, Dublin, Ireland · FEI 30045317905 inspections5latestMay 2, 2025VAINone on file
- Celgene International SarlBoudry, Switzerland · FEI 30063235096 inspections6latestDec 13, 2024VAINone on file
- Juno Therapeutics, Inc.Bothell, Washington · FEI 30118345942 inspections2latestSep 24, 2024NAINone on file
- Bristol-Myers Squibb Pharmaceuticals LimitedWirral, United Kingdom · FEI 30028066021 inspection1latestMay 10, 2023VAINone on file
- Juno Therapeutics, Inc.Seattle, Washington · FEI 30109329122 inspections2latestMar 18, 2022NAINone on file
Other FEIs recorded as Celgene Corporation
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Celgene CorporationFEI 3009081543Berkeley Heights, New Jersey, United States
Last inspected 2015-08-04VAI
Celgene CorporationFEI 3008931128Warren, New Jersey, United States
Last inspected 2013-08-07NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3004991673 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3004991673. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.