Skip to content

Coram Healthcare Corp. of Indiana

1290 Arrowhead Ct Ste A, Crown Point, Indiana, United States

FEI 3004593468

FDA has 2 inspections on file for Coram Healthcare Corp. of Indiana in Crown Point, Indiana (FEI 3004593468), from 2014 to 2017. The latest ended on and was classified OAI, official action indicated. FDA has also posted a Form 483 dated Aug 8, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.

FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2014–2017
2 OAI · 0 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance3 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Materials not disinfected before processing

      Equipment, materials, and/or supplies are not disinfected prior to entering the aseptic processing areas. Specifically, inadequate aseptic practices were observed while transferring materials on 4/18/2017 during the aseptic processing of 7 units of Ertapenem 1 gm/100 ml Rx [illegible] including the following: - Pharmacy technicians wiped down IV bags with sterile IPA but without gloves prior to putting bags in prep room (ISO-8) and then directly moving bags from the prep room (ISO-8) into the hood (ISO-5) without disinfecting the bags; - Vials of sterile drug products were removed from product boxes and were not cleaned. These vials were subsequently placed directly under the hood (ISO-5) without being disinfected; Additionally, while bins that are used for transferring all of the components and ingredients for sterile drug production are wiped down on the inside; these bins are routinely stacked on top of each other with the components such as vials inside. Therefore, vials of active ingredients are touching the bottom of a bin while being transferred from the prep room (ISO-8) to the compounding room (ISO-7) and these vials are subsequently placed directly under the hood (ISO-5) without being disinfected.

    2. Observation 2

      Inadequate sporicidal use and assessment

      The use of sporicidal agents in the cleanroom and/or ISO-5 areas is inadequate. Specifically, the adequacy of cleaning frequency has not been appropriately assessed to ensure potential contaminants are removed from surfaces in the ISO-5 classified area. For example, sporicidal agents that are used on a monthly basis are insufficient to assure the prevention of spores when, on a daily basis, intake materials are not disinfected prior to being placed under the ISO-5 hood. In addition, your firm does not have data to support that the current established contact time of 10 minutes is sufficient to remove sporicidal activity.

    Show observation 3
    1. Observation 3

      Beta-lactam cross-contamination risk

      Beta-lactam drugs are produced without adequate cleaning procedures to prevent cross contamination. Your firm's cleaning procedures are limited to use of sterile water and IPA (70%). There is no dedicated area for processing Beta-lactam products. Your firm has two ISO-5 hoods and beta-lactam products are processed in both. For example 7 units of Ertapenem 1 gm/100 ml Rx [illegible] and 21 units of Vancomycin 1.5 gm/250 ml Rx [illegible] were both processed under the same hood on 4/18/2017. This is a repeat observation.

  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Environmental Monitoring System

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

    2. Sterility/pyrogen-free testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.

    3. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.

    4. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written, and followed.

    5. Clothing appropriate for duties performed

      Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.

    Show 4 more citations
    1. Written program not followed

      The written stability testing program is not followed.

    2. Equipment to control conditions

      Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.

    3. Written record of investigation incomplete

      Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.

    4. Cleaning System

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

Regulations FDA cited here

The 7 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3004593468 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3004593468. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.