FDA has 3 inspections on file for Valgene Incorporated dba Cape Drugs in Annapolis, Maryland (FEI 3004562873), from 2015 to 2021. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDA published 3 citations from this inspection. They are listed below.
The most recent OAI inspection ended on Oct 7, 2015. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2015–2021
- 1 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 3 of 3
- 2 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 citations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
- FDCA 501(a)(2)(A)
Disinfectant contact time
Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection.
- FDCA 501(a)(2)(A)
Cleanliness, ISO-classified areas
The ISO 5 classified aseptic processing areas had difficult to clean and particle-generating equipment or surface.
- FDCA 501(a)(2)(A)
Air flow quality, higher classified area
Your facility design allowed the influx of poor quality air into a higher classified area.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Component identification test
Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Equipment Design, Size and Location
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and suitably located to facilitate operations for its intended use and cleaning and maintenance.
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate aseptic techniques observed
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established. Specifically, On 09/22/2015, during the production of Glutathione 20 mg/ml Injection, lot # 88208, the following aseptic techniques were observed in the cleanroom: A) An aseptic operator was observed placing a benchtop inside the ISO 5 LAFH without [illegible]. The operator proceeded to exit the cleanroom fully gowned and walked into the adjacent unclassified area to wash hands and dry hands with a paper towel before returning back into the unclassified "clean room". This pharmacist was then observed putting on sterile gloves. However, was observed adjusting the glove with bare left hand to fit into the glove. B) An aseptic operator was observed introducing materials into and out of the hood without disinfecting these materials. The operator did not [illegible] the hood to grab material from shelves that are located in the cleanroom. C) Another aseptic operator was also observed introducing material into the hood without disinfecting the surface and also not disinfecting gloves when going back into the hood. This pharmacist was producing ALFA-2B 1 million units/ml ophthalmic. D) An aseptic operator was observed walking multiple times into and out of the unclassified "cleanroom" without putting on any appropriate gowning. Additionally, there is no procedure in place for gowning and nongowning instruction in the gowning area. E) The ISO 5 LAFH is housed in an unclassified room.
- Observation 2
Sterilization process not adequately validated
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process. Specifically, [illegible] after the sterilization [illegible] (5 and 8/5/15) and Dexamethasone acetate (on [illegible]) has [illegible] of Triamcinolone diacetate [illegible] the product should [illegible] stability of the product after [illegible]. D) No media fill has been conducted that simulates routine aseptic operation.
Show observations 3 to 11
- Observation 3
Sterility/endotoxin testing deficiencies
Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements. Specifically, A) Mr. TJW stated that sterility and endotoxin testing of sterile products are conducted [on a] basis. However, endotoxin test result certificates of recently produced products could not be produced by the firm. Mr. TJW stated that endotoxin samples have not been sent to their contract lab for the past 9 months. [illegible] on all sterile drug products produced by your firm. Instead. C) Sterility samples are incubated in-house; however, the firm did not evaluate the sterility samples using [methods] intended to support anaerobic microbes. Furthermore, sterility samples [illegible] is no data that supports the validation of the sterility test.
- Observation 5
Inadequate cleaning/disinfectant validation
Aseptic processing areas are deficient regarding the [procedures] for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, The following non-sterile disinfectants are used for sanitizing the ISO 5 LAFH and the surrounding unclassified "clean [room]". No efficacy study was performed to determine if these [illegible] level in the ISO 5 LAFH and other surfaces (i.e. [illegible]).
- Observation 6
Inappropriate personnel gowning
Clothing of personnel engaged in the manufacturing processing of drug products is not appropriate for the duties they perform. Specifically, On 09/22/2015, two aseptic operators were observed performing aseptic operations in the ISO 5 LAFH wearing non-sterile gowning. Specifically, their coat, face mask, shoe and pants were not sterile. Additionally, their face mask did not cover their skin around their [illegible].
- Observation 7
No calibration/qualification procedures
Procedures describing the calibration of instruments, gauges and recording devices are not written or followed. Specifically, There are no calibration and qualification records for the following equipment: [illegible]. Incubator used for incubating passive air samples, sterility samples and [illegible]. Additionally, there is no procedure in place for calibration and qualification of the above listed equipment.
- Observation 8
Environmental monitoring deficiencies
Aseptic processing areas are deficient regarding the [procedures] for monitoring environmental conditions. Specifically, A) [illegible] in the ISO 5 LAFH during aseptic operations. B) Personnel monitoring is conducted [illegible]. Passive air sampling is conducted on the room with LAFH. C) An Exp. Date 04/09/2015) used for passive air sampling and for fingertip testing was observed.
- Observation 9
HEPA/positive pressure deficiencies
Aseptic processing areas are deficient regarding air that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, [illegible] operations was conducted on [illegible] ic conditions. According to Mr. [illegible].
- Observation 10
Failure to investigate out-of-spec results
There is a failure to thoroughly review any unexplained [illegible] and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. Specifically, No investigation was initiated to determine the root cause for several potency failure results for products produced in 2013, 2012 and 2011. For example, Diethylstilbestrol 1 mg (lot # 49011, dated 10/10/13), "Bactroban, Sporonox, Triam, Xylitol" (lot # 20085, dated 5/31/12), and Bactroban Nasal Spray 0.2% (lot # 2040103, dated 6/6/12) had the following potency results: 80%, 80.5%, and 53.5% respectively, against a specification of [illegible]. Furthermore, there is no procedure in place for conducting investigations.
- Observation 11
No stability testing program
There is no written testing program designed to assess the stability characteristics of drug products. Specifically, The firm does not have a stability program for sterile and non-sterile drug products manufactured at this site. Hydroxocobalamin (B12) 3000 MCG/ml injection, Tobramycin (Ophth) 15 mg/ml Drops and Cisapride 5 mg/ml suspension have an expiration date of 6 months, 1 month, and 2 months respectively.
Regulations FDA cited here
The 3 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.63Equipment design, size, and location1 of 2
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 2
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004562873 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004562873. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.