FDA has 3 inspections on file for Holstein Supply Kansas, Inc in Syracuse, Kansas (FEI 3004414095), from 2013 to 2017. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
Six regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 3, 2013–2017
- 0 OAI · 2 VAI · 1 NAI
- Inspections with 483 observations shown
- 2 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
In-process and laboratory control results
Batch production and control records do not include laboratory control results for each batch of drug product produced.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program .
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt , identification , storage , sampling , testing , approval and rejection of components .
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function , current good manufacturing practices and written procedures required by current good manufacturing practice regulations .
Procedures are written, and followed
Procedures designed to assure that correct labels and labeling are used for drug products are not written .
Show 4 more citations
Lack of quality control unit
There is no quality control unit.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not established and written .
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Written distribution procedure
Written distribution procedures are not established .
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program.
Lack of quality control unit
There is no quality control unit.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, sampling, testing, approval, and rejection of components.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
SOPs not followed / documented
Written production and process control procedures are not followed in the execution of production and process control functions.
Show 4 more citations
Procedures are written, and followed
Procedures designed to assure that correct labels are used for drug products are not written.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Written distribution procedure
Written distribution procedures are not established.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 3 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 2
- 21 CFR 211.25Personnel qualifications2 of 2
- 21 CFR 211.80General requirements2 of 2
- 21 CFR 211.130Packaging and labeling operations2 of 2
- 21 CFR 211.150Distribution procedures2 of 2
- 21 CFR 211.160General requirements2 of 2
- 21 CFR 211.188Batch production and control records2 of 2
- 21 CFR 211.100Written procedures; deviations1 of 2
Show all 11
- 21 CFR 211.137Expiration dating1 of 2
- 21 CFR 211.192Production record review1 of 2
- 21 CFR 211.198Complaint files1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004414095 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004414095. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.