Green Pharmaceuticals, Inc.
591 Constitution Ave Ste A, Camarillo, California, United States
FEI 3004079658DUNS 937749265
FDA has 3 inspections on file for Green Pharmaceuticals, Inc. in Camarillo, California (FEI 3004079658), from 2010 to 2017. The latest ended on and was classified NAI, no action indicated. FDA issued a warning letter on (CDER · Division of Pharmaceutical Quality Operations IV).
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing and labeling, through Dec 31, 2027. Its registrant is Green Pharmaceuticals Inc (D-U-N-S 937749265).
Sources:FDA firm profile ↗Warning letter ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 3, 2010–2017
- 0 OAI · 2 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 3
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER · Division of Pharmaceutical Quality Operations IV ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance10 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Quarantine - actual practice
Drug products are not quarantined before being released by the quality control unit.
Procedures Written and Followed
Procedures describing in sufficient detail the controls employed for the issuance of labeling are not written.
Records reviewed annually
Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
Complaint Investigation/Follow-Up Findings
Complaint records are deficient in that they do not include the findings of the investigation and follow-up.
Show 5 more citations
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Labeling: documentation of exam and review
There is no documentation of the examination and review of labels and labeling for conformity with established specifications.
Retention time of reserve samples, in general
Reserve samples for drug products are not retained for one year after the expiration date of the drug product.
Examinations documented
The results of the examination of the packaged and labeled products were not documented in the batch production or control records.
Labeling Control Records and Label Copies
The batch production and control records are deficient in that they do not include complete labeling control records, specimen, and copy of labeling.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 3 inspections.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.125Labeling issuance1 of 1
- 21 CFR 211.134Drug product inspection1 of 1
- 21 CFR 211.142Warehousing procedures1 of 1
- 21 CFR 211.170Reserve samples1 of 1
- 21 CFR 211.180General requirements1 of 1
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
Show all 10
- 21 CFR 211.192Production record review1 of 1
- 21 CFR 211.198Complaint files1 of 1
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · Division of Pharmaceutical Quality Operations IV · DrugsLetter on fda.govFDA record
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling
- Registration runs through
- Dec 31, 2027
- Registrant
- Green Pharmaceuticals IncD-U-N-S 937749265
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004079658 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004079658. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.