LifeSouth Community Blood Centers Inc - Huntsville Hospital Donor Center
101 Sivley Rd Sw, Huntsville, Alabama, United States
FEI 3004039282
FDA has 5 inspections on file for LifeSouth Community Blood Centers Inc - Huntsville Hospital Donor Center in Huntsville, Alabama (FEI 3004039282), from 2010 to 2018. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 606.100(b), 21 CFR 606.100(c) and 21 CFR 606.160(b).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 5, 2010–2018
- 0 OAI · 2 VAI · 3 NAI
- Inspections with 483 observations shown
- 2 of 5
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Corrective action
Failure to maintain a record of corrective action when the quality control testing for platelets does not meet the prescribed requirements.
Equipment calibration frequency
Equipment used in the collection of blood and blood components is not observed, standardized and calibrated with at least the frequency required.
Quality control
Failure to test each month (of manufacture) four units prepared from different donors at the end of the storage period for platelet count.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection of blood and blood components for homologous transfusion and further manufacturing purposes are not always maintained and followed.
Thorough investigations
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy.
Show 2 more citations
Concurrent documentation
Records are not concurrently maintained with the performance of each significant step in the collection of each unit of blood and blood components so that all steps can be clearly traced.
Required records
Failure to maintain donor, quality control, and general records.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Thorough investigations
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection and processing of blood and blood components for homologous transfusion are not always maintained.
Required records
Failure to maintain donor, quality control, and general records.
Equipment observed, standardized, calibrated
Equipment used in the collection of blood and blood components is not observed, standardized, and calibrated on a regularly scheduled basis as prescribed in the SOP Manual.
Regulations FDA cited here
The 4 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 606.60Equipment2 of 2
- 21 CFR 606.100Standard operating procedures2 of 2
- 21 CFR 606.160Records2 of 2
- 21 CFR 640.25General requirements1 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3004039282 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3004039282. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.