Healthcare Medical & Respiratory Care, Inc
618 Hobson Ave, Hot Springs, Arkansas, United States
FEI 3003572792
FDA has 2 inspections on file for Healthcare Medical & Respiratory Care, Inc in Hot Springs, Arkansas (FEI 3003572792), from 2012 to 2015. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 7 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
The most recent OAI inspection ended on Jul 20, 2012. No warning letter, court action or import refusal is filed under this FEI.
Seven regulations were cited at more than one inspection; they are listed below.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2012–2015
- 1 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Prepared for each batch, include complete information
Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Training--operations, GMPs, written procedures
Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Show 2 more citations
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, testing, approval, and rejection of components.
Testing Each Component for Conformity with Specs
Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance7 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not in writing.
Prepared for each batch, include complete information
Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Training--operations, GMPs, written procedures
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices, and written procedures required by current good manufacturing practice regulations.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Show 2 more citations
Testing Each Component for Conformity with Specs
Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, testing, approval, and rejection of components.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit2 of 2
- 21 CFR 211.25Personnel qualifications2 of 2
- 21 CFR 211.80General requirements2 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures2 of 2
- 21 CFR 211.100Written procedures; deviations2 of 2
- 21 CFR 211.165Testing and release for distribution2 of 2
- 21 CFR 211.188Batch production and control records2 of 2
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3003572792 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3003572792. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.