Patheon Inc.
111 Consumers Dr, Whitby, Canada
FEI 3003516812DUNS 205475333
Company: Patheon Manufacturing Services LLC · Linked by exact D-U-N-S match (079415560) in FDA registration data
FDA has 8 inspections on file for Patheon Inc. in Whitby, Canada (FEI 3003516812), from 2009 to 2023. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published one citation from this inspection, under 21 CFR Part 211, the manufacturing rules for finished drugs. It is listed below. Two FOIA requests asked FDA for 483s from two later inspections that FDA's Data Dashboard doesn't list yet, the latest ending Jan 1, 2024.
4 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant, Patheon Manufacturing Services LLC (D-U-N-S 079415560), has registered 17 other sites.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 8, 2009–2023
- 0 OAI · 5 VAI · 3 NAI
- Inspections with 483 observations shown
- 2 of 8
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 2 requests, latest Sep 29, 2025
- Warning letters
- None on file
- Import refusals
- 4 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Component identity verification
Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that components conform to appropriate standards of identity, strength, quality and purity.
Written record of investigation incomplete
Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
Written procedures fail to include
Written procedures for cleaning and maintenance fail to include description in sufficient detail of methods, equipment and materials used and parameters relevant to the operation.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Two requests to FDA under the Freedom of Information Act named this site, most recently on Sep 29, 2025. Each one asked for a Form 483.
Inspection ending Jan 1, 2024
1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.
- Sep 29, 2025FDA-FOIA-2025-11415Form 483No records found
Inspection ending Apr 21, 2023
1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 + EIR on Dec 16, 2025. FDAgent holds no copy that FDA posted.
- Oct 4, 2024FDA-FOIA-2024-8801Form 483 + EIR· 1 of 6 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 5 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 8 inspections, with how many of them cited each.
- 21 CFR 211.67Equipment cleaning and maintenance1 of 2
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 2
- 21 CFR 211.160General requirements1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.192Production record review1 of 2
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3003516812, one row per refused product line.
4 refusals from 2018-04-20 to 2022-07-28 · charged UNAPPROVED on 4 · FDA sample analysis on 1
FDA firm profile- 2022-07-28
EXHIBITS - OTHER DRUG RELATED ITEMS N.E.C.66YIB99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northern Border Imports8SJ-0000567-5/21/1
- 2022-07-28
EXHIBITS - OTHER DRUG RELATED ITEMS N.E.C.66YIB99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northern Border Imports8SJ-0000567-5/11/1
- 2019-04-04
ANTI-ANEMIC, N.E.C.61CIA99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Northern Border Imports300-1583332-0/11/1
- 2018-04-20
METHYLPREDNISOLONE (GLUCOCORTICOID)64LDY44
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
FDA sample analysis
Division of Northeast ImportsBNI-0064336-9/251/1A
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Patheon Manufacturing Services LLCD-U-N-S 079415560
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Patheon Manufacturing Services LLC (D-U-N-S 079415560) as the registrant for this site and 17 others. Listed: the 12 with the most warning letters, then the most recent inspections. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Thermo Fisher Scientific Cork LimitedCarrigaline, Ireland · FEI 10001703386 inspections6latestSep 7, 2022VAI1 warning letter, Mar 18, 2014
- Patheon UK LimitedSwindon, United Kingdom · FEI 30028072168 inspections8latestJul 7, 2026VAINone on file
- Patheon Manufacturing Services LLCGreenville, North Carolina · FEI 101849516 inspections16latestJun 30, 2026NAINone on file
- Patheon Manufacturing Services LLCRidgefield, New Jersey · FEI 224631512 inspections12latestMay 19, 2026VAINone on file
- Patheon Italia S.p.A.Monza, Italy · FEI 300306580312 inspections12latestFeb 10, 2026VAINone on file
- Patheon Italia S.p.AFerentino, Italy · FEI 300411015712 inspections12latestJan 30, 2026NAINone on file
- Patheon Pharmaceuticals Inc.Cincinnati, Ohio · FEI 151043715 inspections15latestSep 26, 2025VAINone on file
- Patheon Softgels Inc.High Point, North Carolina · FEI 300145136610 inspections10latestJul 17, 2025VAINone on file
- Patheon Austria GmbH & CoKGLinz, Austria · FEI 30028068535 inspections5latestSep 12, 2024VAINone on file
- Patheon Biologics B.V.Groningen, Netherlands · FEI 30026086875 inspections5latestAug 21, 2024VAINone on file
- Patheon France S.A.SBourgoin Jallieu Cedex, France · FEI 30044685535 inspections5latestSep 29, 2023VAINone on file
- Patheon Softgels B.V.Tilburg, Netherlands · FEI 10003848114 inspections4latestMay 17, 2023VAINone on file
Other FEIs recorded as Patheon Inc.
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Patheon Inc.FEI 3000264888Mississauga, Canada
Last inspected 2023-02-24VAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3003516812 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3003516812. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.