Med Resources, Inc.
14805 N Outer 40 Rd Lowr Level, Chesterfield, Missouri, United States
FEI 3003276259DUNS 118154689
Company: Med Resources, Inc. · Linked by exact D-U-N-S match (967854217) in FDA registration data
FDA has 2 inspections on file for Med Resources, Inc. in Chesterfield, Missouri (FEI 3003276259), from 2010 to 2011. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA has not published the citations from this inspection, and FDAgent holds no Form 483 that FDA posted for it. FDA posts only some 483s, so this does not show that none was issued.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, through Dec 31, 2026. Its registrant, Med Resources, Inc. (D-U-N-S 967854217), has registered 1 other site.
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2010–2011
- 0 OAI · 2 VAI · 0 NAI
- Inspections with 483 observations shown
- 1 of 2
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance12 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Approve or reject procedures or specs
The quality control unit lacks responsibility to approve all procedures or specifications impacting on the identity, strength, quality, and purity of drug products.
SOPs not followed / documented
Written production and process control procedures are not.
Written procedures not established/followed
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Calibration/Inspection/Checking not done
Routine calibration of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Training , Education , Experience overall
Employees engaged in the manufacture, processing, packing, and holding of a drug product lack the education and training required to perform their assigned functions.
Show 7 more citations
Lack of quality control unit
There is no quality control unit.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the receipt, approval, and rejection of drug product containers.
Actual vs. theoretical yields not determined
Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing and holding of the drug product.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Expiration date lacking
Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
Written distribution procedure
Written distribution procedures are not established.
Cleaning/maintenance records not kept
Records are not kept for the maintenance, cleaning, sanitizing, and inspection of equipment.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.67Equipment cleaning and maintenance1 of 1
- 21 CFR 211.68Automatic, mechanical, and electronic equipment1 of 1
- 21 CFR 211.80General requirements1 of 1
- 21 CFR 211.100Written procedures; deviations1 of 1
- 21 CFR 211.103Calculation of yield1 of 1
- 21 CFR 211.137Expiration dating1 of 1
Show all 10
- 21 CFR 211.150Distribution procedures1 of 1
- 21 CFR 211.166Stability testing1 of 1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing
- Registration runs through
- Dec 31, 2026
- Registrant
- Med Resources, Inc.D-U-N-S 967854217
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names Med Resources, Inc. (D-U-N-S 967854217) as the registrant for this site and the one other below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- Med Resources of Georgia, Inc. dba Med Resources, Inc.Covington, Georgia · FEI 3030991327Registered; no FDA inspection on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3003276259 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3003276259. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.