Wockhardt Limited
L-1, MIDC Area, Jalgaon Road 43, Chikalthana, Aurangabad, India
FEI 3002808503
FDA has 5 inspections on file for Wockhardt Limited in Aurangabad, India (FEI 3002808503), from 2010 to 2019. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on Mar 17, 2015. FDA issued a warning letter on (CDER). 1 import refusal is filed under this FEI, on . No court action is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 5, 2010–2019
- 2 OAI · 0 VAI · 3 NAI
- Inspections with 483 observations shown
- 1 of 5
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- 1 refusal
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- NAINo objectionable conditions that need follow-upDrugs · Bioresearch MonitoringNone
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance11 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Complaints reviewed by Quality Control Unit
Written procedures describing the handling of complaints do not include provisions for review by the quality control unit of any complaint involving the possible failure of a drug product to meet any of its specifications.
Scientifically sound laboratory controls
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Inadequate number of personnel
The number of qualified personnel is inadequate to perform and supervise the manufacture, processing, packing, and holding of each drug product.
Contamination, chemical or physical change, deterioration
An NDA-Field Alert Report was not submitted within three working days of receipt of information concerning significant chemical, physical, or other change or deterioration in a distributed drug product.
Extent of discrepancy, failure investigations
Investigations of an unexplained discrepancy and a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
Show 6 more citations
Procedures not in writing, fully followed
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Written record of complaint to include findings, follow-up
Written records of investigation of a drug complaint do not include the findings of the investigation and the follow-up.
Items to cover on annual reviews
Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Complaint Handling Procedure
Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
Training , Education , Experience overall
Employees engaged in the manufacture and holding of a drug product lack the training and experience required to perform their assigned functions.
In-process samples representative, identified properly
Samples taken of in-process materials for determination of conformance to specifications are not representative.
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 5 inspections.
- 21 CFR 211.22Responsibilities of quality control unit1 of 1
- 21 CFR 211.25Personnel qualifications1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.180General requirements1 of 1
- 21 CFR 211.192Production record review1 of 1
- 21 CFR 211.198Complaint files1 of 1
- 21 CFR 314.81Other postmarketing reports1 of 1
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3002808503, one row per refused product line.
1 refusal on 2021-05-19 · charged UNAPPROVED on 1 · no FDA sample analysis
FDA firm profile- 2021-05-19
FUROSEMIDE (DIURETIC)64BCY24
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast ImportsSCS-4845164-7/11/7
Other FEIs recorded as Wockhardt Limited
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Wockhardt LimitedFEI 3009278506Aurangabad, India
Last inspected 2016-01-12OAI
Wockhardt LimitedFEI 3005289335Aurangabad, India
Last inspected 2015-05-26OAI
Wockhardt LimitedFEI 3004540156Aurangabad, India
Last inspected 2015-02-13OAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002808503 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002808503. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.