Diabetes Corporation of America
233 Bedford Way, Franklin, Tennessee, United States
FEI 3002708794
FDA has 2 inspections on file for Diabetes Corporation of America in Franklin, Tennessee (FEI 3002708794), from 2015 to 2017. The latest ended on and was classified VAI, voluntary action indicated. FDA has also posted a Form 483 dated Aug 3, 2017 that FDAgent has not matched to an inspection on the Data Dashboard.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.
The most recent OAI inspection ended on Aug 20, 2015. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2015–2017
- 1 OAI · 1 VAI · 0 NAI
- Inspections with 483 observations shown
- 2 of 2
- 2 posted 483s not matched to an inspection
- Warning letters
- · CDER ↗
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance5 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Non-sterile wipes used in ISO 5
Cleaning pads or wipes used in the ISO 5 area are not sterile. Specifically, the (b)(4) wipes used to clean the LAFH (ISO 5 area) are not sterile.
- Observation 2
Particle-generating/dirty equipment in ISO areas
The ISO-classified areas have difficult to clean, particle-generating, or visibly dirty equipment or surfaces. Specifically, a lyophilizer is located in the non-hazardous buffer room (ISO 7), adjacent to LAFH (ISO 5), this equipment contains (b)(4). There are no procedures for external cleaning and disinfection of this equipment. Also, environmental conditions of the non-hazardous buffer room including but not limited to air flow patterns, viable and non-viable particles have not been evaluated during operation of the lyophilizer.
Show observations 3 to 5
- Observation 3
Glove hygiene breaches during aseptic processing
Personnel were observed touching equipment or other surfaces located outside of the ISO 5 area with gloved hands and then proceeding with aseptic processing without changing or sanitizing gloves. Specifically, on 06/05/2017, I observed clean room operator, with initials (b)(4), perform drug product aseptic transfers in the LAFH (ISO 5). The operator did not always disinfect or change gloves after leaving the LAFH to retrieve materials or discard waste. The following lots were produced without glove disinfection/changes: - [illegible] - Phenylepherine/LIDO, RX [illegible]
- Observation 4
Released products failed integrity tests
Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess. Specifically, post production (b)(4) integrity tests performed by your firm have failed to meet the (b)(4) manufacturer's specifications for (b)(4). No investigations were performed and the batches were released for distribution. The following batches all had recorded (b)(4) values below the manufacturer's specification (list is not all inclusive): - Tri-mix 4 injectable, lot: 060117wc - Oxytocin nasal spray 40u/ml, lot: 053117bm - Glutathione 200mg/ml injectable, lot: 022417bm
- Observation 5
Inadequate media fill simulation
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, your firm's batch sizes for injectable drug products range from (b)(4) to (b)(4). However, the last media fill performed only consisted of (b)(4).
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Equipment to control conditions
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Clothing appropriate for duties performed
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room to produce aseptic conditions.
Show 4 more citations
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Containers & Closures Clean, Sterilized, Pyrogen-free
Drug product containers and closures were not sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.
Establishment of time limitations
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.
- 21 CFR 211.28Personnel responsibilities1 of 1
- 21 CFR 211.42Design and construction features1 of 1
- 21 CFR 211.94Drug product containers and closures1 of 1
- 21 CFR 211.111Time limitations on production1 of 1
- 21 CFR 211.113Control of microbiological contamination1 of 1
- 21 CFR 211.166Stability testing1 of 1
- 21 CFR 211.167Special testing requirements1 of 1
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3002708794 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3002708794. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.