Skip to content

San Diego Eye Bank

3870 Murphy Canyon Rd Ste 250, San Diego, California, United States

FEI 3002515992

FDA has 6 inspections on file for San Diego Eye Bank in San Diego, California (FEI 3002515992), from 2009 to 2024. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

FDA published 2 citations from this inspection, all under 21 CFR Part 1271, the rules for human cell and tissue products. They are listed below. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 1271.75(d) and 21 CFR 1271.230(a).

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
6, 2009–2024
0 OAI · 2 VAI · 4 NAI
Inspections with 483 observations shown
3 of 6
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
1 request, latest May 17, 2024
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood Products2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Donors with risks not determined ineligible

      Donors were not determined to be ineligible that had risk factors or clinical evidence of communicable disease agents.

    2. Design of procedures to ensure compliance

      Procedures were not designed to ensure compliance with the donor eligibility requirements.

  2. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  3. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  4. NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies4 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Monitoring systems

      The quality program has not established and maintained appropriate monitoring systems.

    2. Quality audits performed periodically

      Periodic quality audits of activities related to core CGTP requirements have not been performed.

    3. Monitoring-microorganisms where appropriate

      Environmental conditions were not monitored for microorganisms.

    4. Process validation procedures

      Procedures to validate and approve processes that cannot be fully verified by inspection and tests were not defined and followed.

  6. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies8 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Process validation procedures

      Procedures to validate and approve processes that cannot be fully verified by inspection and tests were not established, defined, and documented.

    2. Donors with risks not determined ineligible

      Donors were not determined to be ineligible that had risk factors or clinical evidence of communicable disease agents.

    3. Shipping conditions appropriate

      Appropriate shipping conditions were not established and defined for each type of HCT/P.

    4. Ensuring appropriate core requirements followed

      The quality program has not ensured that appropriate procedures related to core CGTP requirements were established, defined, and followed.

    5. Return to inventory--procedures

      Procedures for determining if HCT/Ps that were returned to the establishment are suitable to be returned to inventory were not defined.

    Show 3 more citations
    1. Procedures to meet core CTGP

      Procedures appropriate to meet core CGTP requirements for all steps that you perform in the manufacture of HCT/Ps were not established and defined.

    2. Deviations--evaluation, cause, corrective action

      Investigation of deviations related to core CGTP requirements did not include a review and evaluation of the deviation, efforts to determine the cause of the deviation, and corrective action(s) to address the deviation and prevent recurrence.

    3. Procedures re complaints

      Procedures for the evaluation, documentation, and investigation of complaints relating to CGTP requirements were not defined and followed.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on May 17, 2024. It asked for a Form 483.

  • Inspection ending May 3, 2024NAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. May 17, 2024FDA-FOIA-2024-4480Form 483· 1 of 2 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3002515992 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3002515992. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.