Lions Eye Bank of Wisconsin, Inc.
5003 Tradewinds Pkwy, Madison, Wisconsin, United States
FEI 3000718534
FDA has 6 inspections on file for Lions Eye Bank of Wisconsin, Inc. in Madison, Wisconsin (FEI 3000718534), from 2010 to 2023. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
One FOIA request asked FDA for the 483 from a later inspection, ending Jul 6, 2026, that FDA's Data Dashboard doesn't list yet.
No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 1271.160(c).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 6, 2010–2023
- 0 OAI · 3 VAI · 3 NAI
- Inspections with 483 observations shown
- 3 of 6
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 1 request, latest Sep 9, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Documentation/approval prior to implementation
Computer software verification activities and results have not been documented and approved prior to implementation.
Ensuring appropriate core requirements followed
The quality program has not ensured that appropriate procedures related to core CGTP requirements were established and implemented.
Responsibility for review before distribution
HCT/Ps were determined to meet all release criteria and made available for distribution without review of manufacturing records to determine that all applicable requirements were met.
Process validation procedures
Procedures to validate and approve processes that cannot be fully verified by inspection and tests were not documented.
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene TherapiesNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Ensurane of compliance
You did not ensure that establishment(s) that by contract, agreement or arrangement, perform manufacturing steps for you were in compliance with applicable CGTP requirements prior to the initiation of the contract, agreement of arrangement.
Risk factors, clinical evidence
Donors were not screened by a review of relevant medical records for risk factors of communicable disease agents and diseases.
Quality audits performed periodically
Periodic quality audits of activities related to core CGTP requirements have not been performed.
Ten year retention
Records pertaining to HCT/Ps were not retained at least 10 years after the date of administration.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Human Cellular, Tissue, and Gene Therapies5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures and release criteria
Procedures including release criteria for activities relating to the shipment of HCT/Ps were not maintained.
Use prior to verification
Supplies and reagents were used before they were verified to meet specifications designed to prevent the introduction, transmission, or spread of communicable disease.
Actions taken and documented
The quality program has not ensured that appropriate corrective actions relating to core CGTP requirements are taken.
Quality audits performed periodically
Periodic quality audits of activities related to core CGTP requirements have not been performed.
Program is appropriate for the HCT/Ps
A quality program appropriate for the HCT/Ps manufactured and manufacturing steps performed has not been maintained.
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Sep 9, 2026. It asked for a Form 483.
Inspection ending Jul 6, 2026
1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Sep 30, 2026. FDAgent holds no copy that FDA posted.
- Sep 9, 2026FDA-FOIA-2026-8736Form 483· 1 of 3 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 1271.160Establishment and maintenance of a quality program3 of 3
- 21 CFR 1271.150Current good tissue practice requirements2 of 3
- 21 CFR 1271.55What records must accompany an HCT/P after the donor-eligibility determination is complete; and what records must I retain?1 of 3
- 21 CFR 1271.75How do I screen a donor?1 of 3
- 21 CFR 1271.210Supplies and reagents1 of 3
- 21 CFR 1271.230Process validation1 of 3
- 21 CFR 1271.265Receipt, predistribution shipment, and distribution of an HCT/P1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3000718534 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3000718534. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.