North Colorado Medical Center Blood Bank
1801 16th St, Greeley, Colorado, United States
FEI 1774110
FDA has 6 inspections on file for North Colorado Medical Center Blood Bank in Greeley, Colorado (FEI 1774110), from 2010 to 2022. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 606.100(b), 21 CFR 606.165(a) and 21 CFR 606.160(b).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 6, 2010–2022
- 0 OAI · 2 VAI · 4 NAI
- Inspections with 483 observations shown
- 3 of 6
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Thorough investigations
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy.
Distribution and receipt - recalls
Failure of distribution and receipt procedures to include a system by which the distribution or receipt of each unit can be readily determined to facilitate its recall.
Quality control unit review of records
Drug product production and control records, are not reviewed by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Biological product deviation report
Failure to submit a biological product deviation report within 45 days from the date you acquired information suggesting that a reportable event occurred.
Concurrent documentation
Records are not concurrently maintained with the performance of each significant step in the distribution of each unit of blood and blood components so that all steps can be clearly traced.
Show 1 more citation
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the distribution of blood and blood components for homologous transfusion and autologous transfusion are not always maintained and followed.
- NAINo objectionable conditions that need follow-upBiologics · Human Cellular, Tissue, and Gene Therapies2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the distribution of blood and blood components for homologous transfusion are not always followed.
Required records
Failure to maintain donor records.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products8 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Procedures To Be in Writing
Written procedures are lacking which describe in sufficient detail the sampling, testing, approval, and rejection of components.
Distribution and receipt - recalls
Failure of distribution and receipt procedures to include a system by which the distribution or receipt of each unit can be readily determined to facilitate its recall.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection of blood and blood components for homologous transfusion are not always followed.
Quality control
Failure to test each month (of manufacture) four units prepared from different donors at the end of the storage period for platelet count, pH of not less than 6.0 measured at the storage temperature of the unit, and actual plasma volume.
Required records
Failure to maintain donor and general records.
Show 3 more citations
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy and completeness.
Provisions to monitor lab test procedures & instruments
Failure to establish adequate provisions for monitoring the reliability, accuracy, precision, and performance of laboratory test procedures and instruments.
Test methods
The accuracy, specificity, and reproducibility of test methods have not been established and documented.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 6 inspections, with how many of them cited each.
- 21 CFR 606.100Standard operating procedures3 of 3
- 21 CFR 606.160Records3 of 3
- 21 CFR 606.165Distribution and receipt; procedures and records2 of 3
- 21 CFR 211.80General requirements1 of 3
- 21 CFR 211.165Testing and release for distribution1 of 3
- 21 CFR 211.192Production record review1 of 3
- 21 CFR 211.194Laboratory records1 of 3
- 21 CFR 606.140Laboratory controls1 of 3
Show all 10
- 21 CFR 606.171Reporting of product deviations by licensed manufacturers, unlicensed registered blood establishments, and transfusion services1 of 3
- 21 CFR 640.25General requirements1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1774110 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1774110. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.