FDA has 10 inspections on file for DPT Laboratories, Ltd in San Antonio, Texas (FEI 1628114), from 2009 to 2024. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
One of the three FOIA requests for this site has asked FDA for this inspection's records.
7 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is Viatris Inc. (D-U-N-S 117542494).
Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 10, 2009–2024
- 0 OAI · 3 VAI · 7 NAI
- Inspections with 483 observations shown
- 2 of 10
- Form 483s posted by FDA
- None held for this FEI
- Requested under FOIA
- 3 requests, latest Feb 6, 2025
- Warning letters
- None on file
- Import refusals
- 7 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
10 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Written records kept in individual logs
Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.
Identification of Equipment and Lines
The batch production and control records are deficient in that they do not include the identity of major equipment used.
Authority lacking to review records, investigate errors
The quality control unit lacks authority to fully investigate errors that have occurred.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Sampling and testing plans not followed
Written procedures for sampling and testing plans are not followed for each drug product.
Procedures to be written and followed
Procedures describing the handling of all written and oral complaints regarding a drug product are not followed.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Feb 6, 2025.
Inspection ending May 29, 2024NAI
1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.
- Feb 6, 2025FDA-FOIA-2025-1192EIRClosed
Inspection date not given
2 requests. None of FDA’s log entries for these requests say records were released.
- Jul 11, 2022FDA-FOIA-2022-4985Form 483 + EIR· 1 of 3 sitesWithdrawn
- Jul 1, 2022FDA-FOIA-2022-4799Inspection recordsNo records found
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.
Regulations FDA cited here
The 5 sections of 21 CFR in FDA’s published citations for 2 of this facility’s 10 inspections, with how many of them cited each.
- 21 CFR 211.22Responsibilities of quality control unit1 of 2
- 21 CFR 211.165Testing and release for distribution1 of 2
- 21 CFR 211.182Equipment cleaning and use log1 of 2
- 21 CFR 211.188Batch production and control records1 of 2
- 21 CFR 211.198Complaint files1 of 2
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1628114, one row per refused product line.
7 refusals from 2018-03-28 to 2018-07-24 · charged UNAPPROVED on 6, AGR RX on 1 · no FDA sample analysis
FDA firm profile- 2018-07-24
ENZYME INHIBITOR N.E.C.64FCJ99
AGR RX 801(d)(1),(2); IMPORTATION RESTRICTED
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of Southeast Imports231-0585659-0/11/1
- 2018-06-28
ENZYME INHIBITOR N.E.C.64FCJ99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports231-0588536-7/31/1
- 2018-06-28
ENZYME INHIBITOR N.E.C.64FCJ99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports231-0588536-7/21/1
- 2018-06-28
ENZYME INHIBITOR N.E.C.64FCJ99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports231-0588536-7/11/1
- 2018-03-28
ENZYME INHIBITOR N.E.C.64FCJ99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports231-0588467-5/31/1
Show 2 more
- 2018-03-28
ENZYME INHIBITOR N.E.C.64FCJ99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports231-0588467-5/21/1
- 2018-03-28
ENZYME INHIBITOR N.E.C.64FCJ99
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports231-0588467-5/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- Manufacturing, packing, labeling, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- Viatris Inc.D-U-N-S 117542494
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1628114 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1628114. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.