Skip to content

Fresenius Kabi USA LLC

2085 N Hawthorne Ave, Melrose Park, Illinois, United States

FEI 1450022DUNS 023648251

Company: Fresenius Kabi USA, LLC · Linked by exact D-U-N-S match (608775388) in FDA registration data

FDA has 14 inspections on file for Fresenius Kabi USA LLC in Melrose Park, Illinois (FEI 1450022), from 2009 to 2023. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA published one citation from this inspection, under 21 CFR Part 211, the manufacturing rules for finished drugs. It is listed below. Two of the 18 FOIA requests for this site have asked FDA for this inspection's 483, and four more for the 483 from a later inspection, ending Feb 18, 2026, that FDA's Data Dashboard doesn't list yet.

The most recent OAI inspection ended on Jun 30, 2022. No warning letter, court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 211.22(d) and 21 CFR 211.113(b).

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing and analysis, through Dec 31, 2027. Its registrant, Fresenius Kabi USA, LLC (D-U-N-S 608775388), has registered 3 other sites.

Sources:FDA firm profile ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
14, 2009–2023
2 OAI · 4 VAI · 8 NAI
Inspections with 483 observations shown
5 of 14
Form 483s posted by FDA
↗
Requested under FOIA
18 requests, latest FY2023
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

14 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

  2. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssuranceCitations not published
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 6 citations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Establishment of time limitations

      Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

    2. Written procedures not established/followed

      Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.

    3. Batch production and Batch Control Record Requirements

      The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing and packing.

    4. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.

    5. Investigations of discrepancies, failures

      There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

    Show 1 more citation
    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.

  4. NAINo objectionable conditions that need follow-upDevices · Postmarket Assurance: DevicesNone
  5. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Visual inspection

      The packaging and labeling operation involving cut labels and relying on visual inspection does not provide for examination to be performed by one person and independently verified by a second person .

  7. NAINo objectionable conditions that need follow-upDevices · Compliance: Devices3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Procedures for sterile drug products

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.

    2. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its cleaning and maintenance.

    3. Procedures not in writing, fully followed

      The responsibilities and procedures applicable to the quality control unit are not fully followed.

  8. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  9. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  10. NAINo objectionable conditions that need follow-upDevices · Compliance: DevicesNone
  11. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  12. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  13. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Investigations made into any unexplained discrepancy

      Batch production and control records do not include the results of any investigation made into any unexplained discrepancy, whether or not the batch of drug product had already been distributed.

  14. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

18 requests to FDA under the Freedom of Information Act named this site, most recently on FY2023.

  • Inspection ending Feb 18, 2026

    4 requests. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on May 12, 2026. FDAgent holds no copy that FDA posted.

    1. May 27, 2026FDA-FOIA-2026-5290Form 483· 1 of 3 sitesOpen
    2. May 11, 2026FDA-FOIA-2026-4853Form 483· 1 of 5 sitesRecords released
    3. May 6, 2026FDA-FOIA-2026-4585Form 483Records released
    4. Apr 27, 2026FDA-FOIA-2026-4191Form 483Records released
  • Inspection ending Aug 24, 2023VAI

    2 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on May 28, 2026. FDAgent holds no copy that FDA posted.

    1. May 14, 2026FDA-FOIA-2026-4955Form 483Records released
    2. Oct 6, 2023FDA-FOIA-2023-8771Form 483Closed
  • Inspection ending Jun 30, 2022OAI

    3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on May 28, 2026. FDAgent holds no copy that FDA posted.

    1. FY2023FDA-FOIA-2023-2744Form 483 + EIRWithdrawn
    2. May 14, 2026FDA-FOIA-2026-4960Form 483Records released
    3. Mar 18, 2024FDA-FOIA-2024-2680EIRWithdrawn
  • Inspection ending May 18, 2020OAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Mar 18, 2024FDA-FOIA-2024-2681EIRWithdrawn
  • Inspection date not given

    8 requests. FDA released records in answer to a request for its Form 483 on Sep 30, 2025. FDAgent holds no copy that FDA posted.

    1. FY2023FDA-FOIA-2023-1074Form 483Closed
    2. FY2023FDA-FOIA-2022-8207Form 483Closed
    3. Oct 9, 2026FDA-FOIA-2026-9854Form 483Records released
    4. Aug 10, 2026FDA-FOIA-2026-7647Form 483 + EIRClosed
    5. Sep 30, 2025FDA-FOIA-2025-11450Form 483Closed
    6. Sep 24, 2025FDA-FOIA-2025-11222Form 483Records released
    7. Dec 27, 2021FDA-FOIA-2021-8865Form 483No records found
    8. Sep 24, 2021FDA-FOIA-2021-6368Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 14 inspections, with how many of them cited each.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, analysis
Registration runs through
Dec 31, 2027
Registrant
Fresenius Kabi USA, LLCD-U-N-S 608775388

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Fresenius Kabi USA, LLC (D-U-N-S 608775388) as the registrant for this site and the 3 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Other FEIs recorded as Fresenius Kabi USA LLC

Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 1450022 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 1450022. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.