American Red Cross Blood Services
209 Farmington Ave, Farmington, Connecticut, United States
FEI 1273014
FDA has 13 inspections on file for American Red Cross Blood Services in Farmington, Connecticut (FEI 1273014), from 2008 to 2026. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on Jun 15, 2010. No warning letter, court action or import refusal is filed under this FEI.
Two regulations were cited at more than one inspection: 21 CFR 211.56(a) and 21 CFR 606.100(b).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 13, 2008–2026
- 1 OAI · 5 VAI · 7 NAI
- Inspections with 483 observations shown
- 6 of 13
- 2 posted 483s not matched to an inspection
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
13 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Retention period
Failure to retain records.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not free of infestation by rodents, birds insects, and other vermin.
Defined areas of adequate size for operations
The separate or defined areas and control systems necessary to prevent contamination or mix-ups are deficient.
Yield calculations not verified by 2nd person
Yield calculations are not performed by one person and independently verified by a second person.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection, processing, storage, and distribution of blood and blood components for homologous transfusion are not always followed.
Thorough investigations
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy.
- OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Blood and Blood Products5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
No written record of investigation
Written records are not always made of investigations into unexplained discrepancies.
Second person sign off
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness, and compliance with established standards.
- n/a
Procedural requirements
Deviation from the procedural requirements of a decree of injunction.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection of blood and blood components for further manufacturing purposes are not always followed.
Qualifications of responsible personnel
The personnel responsible for the collection of blood or blood components are not adequate in number to assure competent performance of their assigned functions, and to ensure that the final product has the safety, purity, potency, identity and effectiveness it purports or is represented to possess.
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Sanitation--buildings not clean, free of infestation
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition and free of infestation by rodents, birds insects, and other vermin.
Written sanitation procedures lacking
There is a lack of written procedures providing cleaning schedules and describing in sufficient detail the methods, equipment and materials to be used for sanitation.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Failure to prevent distribution without ice
Failure to adequately investigate, correct, and prevent recurring problem of distributing blood and blood components without ice to consignees. Specifically, a. The problem for [illegible] was discovered on 3/20/08. The problem involved shipment of 16 red blood cells without ice to a consignee. This was a [illegible] investigation. The consignee was instructed to destroy the units by [illegible] Hospital Services Supervisor referred [illegible] (JO). No hold was placed on the units. A corrective action, and a three months effectiveness check from June to August were developed [illegible] implemented. On 9/9/08 during QA review of [illegible] resulted in problem [illegible] to address why units were not placed on hold. b. On 7/16/08 another incident regarding Shipment of red cell without ice to consignee occurred; an exception was opened on 7/17/08. The problem involved distribution of 23 red blood cell without ice to consignee. This issue also resulted in consignee being instructed to destroy the units by [illegible] No hold was placed on the units. A corrective action was developed and implemented; and [illegible] months effectiveness checks from September to November was implemented.
- Observation 2
Suspect product procedure not followed
Written procedure was not followed regarding handling of "Management of Suspect Products". Specifically, [illegible] 7/17/08 [illegible] and [illegible] Hospital Services Supervisor (JO) instructed [illegible] to destroy units, instead of referring the customer complaints to ARC, [illegible] follow up, as it's written apply the appropriate [illegible] both cases, Hospital Service [illegible]
Show observation 3
- Observation 3
Unsigned equipment validation records
Failure to sign and date equipment validation/revalidation records. Specifically, Equipment ID's: [illegible] not sign/date; and the work order [illegible]
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 13 inspections, with how many of them cited each.
- 21 CFR 211.56Sanitation2 of 5
- 21 CFR 606.100Standard operating procedures2 of 5
- 21 CFR 211.42Design and construction features1 of 5
- 21 CFR 211.103Calculation of yield1 of 5
- 21 CFR 211.192Production record review1 of 5
- 21 CFR 211.194Laboratory records1 of 5
- 21 CFR 606.20Personnel1 of 5
- 21 CFR 606.160Records1 of 5
Observations read from posted 483 PDFs carry no CFR section of FDA’s, so they are not counted here.
Other FEIs recorded as American Red Cross Blood Services
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
American Red Cross Blood ServicesFEI 1000158579Marietta, Georgia, United States
Last inspected 2025-03-05NAI
American Red Cross Blood ServicesFEI 1073001Birmingham, Alabama, United States
Last inspected 2025-02-26NAI
American Red Cross Blood ServicesFEI 3003506975Atlanta, Georgia, United States
Last inspected 2024-12-03NAI
American Red Cross Blood ServicesFEI 1000221279Scranton, Pennsylvania, United States
Last inspected 2024-10-10NAI
American Red Cross Blood ServicesFEI 1973037Omaha, Nebraska, United States
Last inspected 2024-09-30NAI
American Red Cross Blood ServicesFEI 2076545Santa Ana, California, United States
Last inspected 2024-07-03NAI
American Red Cross Blood ServicesFEI 3002571149Boston, Massachusetts, United States
Last inspected 2024-06-14NAI
American Red Cross Blood ServicesFEI 3005192209Pewaukee, Wisconsin, United States
Last inspected 2024-04-24NAI
American Red Cross Blood ServicesFEI 1000119273Omaha, Nebraska, United States
Last inspected 2024-02-08NAI
American Red Cross Blood ServicesFEI 1000115425Goshen, Indiana, United States
Last inspected 2024-01-31NAI
Not every site is listed: these are the most recently inspected sites found under this name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1273014 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1273014. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.