FDA has 5 inspections on file for Grifols Bio Supplies Inc in Miami, Florida (FEI 1049760), from 2010 to 2026. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
The most recent OAI inspection ended on Oct 20, 2010. No warning letter, court action or import refusal is filed under this FEI.
One regulation was cited at more than one inspection: 21 CFR 606.100(b).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 5, 2010–2026
- 1 OAI · 2 VAI · 2 NAI
- Inspections with 483 observations shown
- 3 of 5
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
5 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
When to report
Biological product deviations were not reported within the 45 calendar day timeframe.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection and processing of blood and blood components for further manufacturing purposes were not always established, maintained and followed.
CPR certification
Failure to assure that an individual who is currently certified in cardiopulmonary resuscitation is located on the premises whenever collections of blood or blood components are performed.
Additional Medical Assessment Factors
Medical history assessment failed to include factors that make the donor ineligible to donate when donating could adversely affect the health of the donor or the safety, purity, or potency of the blood or blood component could be affected adversely by travel to, or residence in, an area endemic for a transfusion-transmitted infection and the donor being a xenotransplantation product recipient.
Following manufacturer's instructions
Failure to use supplies and reagents in a manner consistent with instructions provided by the manufacturer.
- OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Blood and Blood Products9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Concurrent documentation
Records are not concurrently maintained with the performance of each significant step in the collection of each unit of blood and blood components so that all steps can be clearly traced.
Exclusion of certain persons
Failure to exclude persons whose presence can adversely affect the safety and purity of the products from areas where the collection of blood or blood components is conducted.
Collection
Failure to ensure that source material is collected using appropriate methods.
Donor suitability determined by unqualified person
Failure to determine the suitability of a donor as a source of blood by a qualified physician or by a person under his supervision and trained in determining suitability.
Notification w/in 8 weeks
Failure to make reasonable attempts to notify the donor within 8 weeks after determining that the donor is deferred or determined not to be suitable for donation.
Show 4 more citations
Donor suitability procedures not followed
Failure to follow standard procedures and methods for determining the suitability of a donor as a source of blood.
Thorough investigations
Failure to perform a thorough investigation of an unexplained discrepancy.
Qualifications of responsible personnel
The personnel responsible for the collection of blood or blood components are not adequate in training and experience, including professional training as necessary to assure competent performance of their assigned functions, and to ensure that the final product has the safety, purity, potency, identity and effectiveness it purports or is represented to possess.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection and processing of blood and blood components for further manufacturing purposes are not always maintained and followed.
Regulations FDA cited here
The 10 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 5 inspections, with how many of them cited each.
- 21 CFR 606.100Standard operating procedures2 of 3
- 21 CFR 600.14Reporting of biological product deviations by licensed manufacturers1 of 3
- 21 CFR 606.20Personnel1 of 3
- 21 CFR 606.65Supplies and reagents1 of 3
- 21 CFR 606.160Records1 of 3
- 21 CFR 630.5Medical supervision1 of 3
- 21 CFR 630.10General donor eligibility requirements1 of 3
- 21 CFR 630.40Requirements for notifying deferred donors1 of 3
Show all 10
- 21 CFR 640.31 of 3
- 21 CFR 640.52Collection of source material1 of 3
Other FEIs recorded as Grifols Bio Supplies Inc
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Grifols Bio Supplies IncFEI 1033225Memphis, Tennessee, United States
Last inspected 2026-04-29NAI
Grifols Bio Supplies IncFEI 3013448338Miami, Florida, United States
Last inspected 2025-03-12NAI
Grifols Bio Supplies IncFEI 3000719222Philadelphia, Pennsylvania, United States
Last inspected 2024-08-13NAI
Grifols Bio Supplies IncFEI 1075656Memphis, Tennessee, United States
Last inspected 2024-02-14NAI
Grifols Bio Supplies IncFEI 1000306122Temple, Texas, United States
Last inspected 2022-08-29NAI
Grifols Bio Supplies IncFEI 3013456535Memphis, Tennessee, United States
Last inspected 2021-12-09NAI
Grifols Bio Supplies IncFEI 1071903Memphis, Tennessee, United States
Last inspected 2021-09-08NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1049760 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1049760. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.