Grifols Bio Supplies Inc
1250 N Broad St # 52, Philadelphia, Pennsylvania, United States
FEI 3000719222
FDA has 8 inspections on file for Grifols Bio Supplies Inc in Philadelphia, Pennsylvania (FEI 3000719222), from 2009 to 2024. The latest ended on and was classified NAI, no action indicated.
NAI means FDA found no objectionable conditions or practices, or found none that justified further action.
No warning letter, court action or import refusal is filed under this FEI.
Three regulations were cited at more than one inspection: 21 CFR 660.32, 21 CFR 630.40(a) and 21 CFR 606.100(c).
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- NAI
- Inspections on file
- 8, 2009–2024
- 0 OAI · 5 VAI · 3 NAI
- Inspections with 483 observations shown
- 5 of 8
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
8 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Cumulative deferral record HTLV, Chagas
Failure to maintain at all locations operating under the same license or under common management a cumulative record of donors deferred from donation under the regulations based on reactive testing for evidence of infection due to HTLV or Chagas disease.
Test for HTLV, syphilis, West Nile, Chagas
Failure to test each donation of blood and blood components intended for transfusion or for use in manufacturing a product for evidence of infection with Chagas disease.
Additional Medical Assessment Factors
Medical history assessment failed to include factors that make the donor ineligible to donate when donating could adversely affect the health of the donor or the safety, purity, or potency of the blood or blood component could be affected adversely by exposure or possible exposure to an accidentally or intentionally released disease or disease agent relating to a transfusion-transmitted infection and the donor being a xenotransplantation product recipient.
Donor's Acknowledgment - Exculpatory language
The donor acknowledgment did not address the donor’s review of educational material regarding relevant transfusion-transmitted infections, did not address the donor’s agreement to not donate if the donation could result in a potential risk to recipients and did not address an opportunity for the donor to ask question and withdraw from the donation procedure.
Proof Of Identity
Failure to obtain from the donor on the day of donation a postal address where the donor may be contacted for 8 weeks after donation.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products1 citation published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Notification
Failure to make reasonable attempts to notify a donor who has been deferred based on the results of tests for evidence of communicable disease agent(s).
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Thorough investigations
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of a failure of a lot or unit to meet any of its specifications.
Same as for whole blood
Blood for reagent red blood cells is not collected from peripheral donors as prescribed under applicable sections of the regulation for the collection of whole blood.
- NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products5 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Notification
Failure to make reasonable attempts to notify a donor who has been deferred based on the results of tests for evidence of communicable disease agent(s).
Donor suitability procedures not followed
Failure to follow standard procedures and methods for determining the suitability of a donor as a source of blood.
Thorough investigations
Failure to perform a thorough investigation and make a record of the conclusions and follow-up of a failure of a lot or unit to meet any of its specifications.
Same as for whole blood
Blood for reagent red blood cells is not collected from peripheral donors as prescribed under applicable sections of the regulation for the collection of whole blood.
Establish, maintain and follow manufacturing SOPs
Written standard operating procedures including all steps to be followed in the collection of blood and blood components for further manufacturing purposes are not always followed.
- VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Same as for whole blood
Blood for reagent red blood cells is not collected from peripheral donors as prescribed under applicable sections of the regulation for the collection of whole blood.
Same as for whole blood donor
Donors of peripheral blood for reagent red blood cells did not meet the appropriate criteria in the regulations for donor suitability as a source of whole blood.
Regulations FDA cited here
The 8 sections of 21 CFR in FDA’s published citations for 5 of this facility’s 8 inspections, with how many of them cited each.
- 21 CFR 660.32Collection of source material3 of 5
- 21 CFR 606.100Standard operating procedures2 of 5
- 21 CFR 630.40Requirements for notifying deferred donors2 of 5
- 21 CFR 606.160Records1 of 5
- 21 CFR 610.40Test requirements1 of 5
- 21 CFR 630.10General donor eligibility requirements1 of 5
- 21 CFR 640.31 of 5
- 21 CFR 660.31Eligibility of donor1 of 5
Other FEIs recorded as Grifols Bio Supplies Inc
Matched on the exact firm name FDA recorded. Sites recorded under other names are not listed, and a shared name does not show common ownership.
Grifols Bio Supplies IncFEI 1033225Memphis, Tennessee, United States
Last inspected 2026-04-29NAI
Grifols Bio Supplies IncFEI 1049760Miami, Florida, United States
Last inspected 2026-04-23NAI
Grifols Bio Supplies IncFEI 3013448338Miami, Florida, United States
Last inspected 2025-03-12NAI
Grifols Bio Supplies IncFEI 1075656Memphis, Tennessee, United States
Last inspected 2024-02-14NAI
Grifols Bio Supplies IncFEI 1000306122Temple, Texas, United States
Last inspected 2022-08-29NAI
Grifols Bio Supplies IncFEI 3013456535Memphis, Tennessee, United States
Last inspected 2021-12-09NAI
Grifols Bio Supplies IncFEI 1071903Memphis, Tennessee, United States
Last inspected 2021-09-08NAI
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3000719222 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3000719222. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.