Laboratoria Qualiphar NV
Rijksweg 9, Bornem, Belgium
FEI 1000627334
FDA has one inspection on file for Laboratoria Qualiphar NV in Bornem, Belgium (FEI 1000627334). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).
OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.
FDA published 9 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
6 import refusals are filed under this FEI, the latest on . FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- OAI
- Inspections on file
- 1, in 2010
- Inspections with 483 observations shown
- 1 of 1
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- · CDER ↗
- Import refusals
- 6 refusals
- Import alerts
- 66-40Red List
- Matched on FDA’s firm name and street address
Inspection history
1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Control procedures to monitor and validate performance
Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Following/documenting laboratory controls
Established laboratory control mechanisms are not followed.
Reprocessing procedures not written or followed
Procedures prescribing a system for reprocessing batches to insure that the reprocessed batches will conform with all established standards, specifications, and characteristics are not written.
Actual yield, % of theoretical yield
The batch production and control records do not include a statement of the actual yield at appropriate stages of processing for each batch of drug product produced.
Records of any sampling performed
Batch production and control records do not include a record of any sampling performed, for each batch of drug product produced.
Show 4 more citations
Written in-process control procedures
Written procedures are not followed that describe the in-process controls to be conducted on appropriate samples of in-process materials of each batch.
Dedicated equipment: records part of batch record
The records of use for dedicated equipment are not part of the batch record.
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
Records of disposition of rejected material
Records do not include the disposition of rejected drug product containers.
Regulations FDA cited here
The 7 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.
- 21 CFR 211.110Sampling and testing of in-process materials and drug products1 of 1
- 21 CFR 211.115Reprocessing1 of 1
- 21 CFR 211.160General requirements1 of 1
- 21 CFR 211.180General requirements1 of 1
- 21 CFR 211.182Equipment cleaning and use log1 of 1
- 21 CFR 211.184Component, drug product container, closure, and labeling records1 of 1
- 21 CFR 211.188Batch production and control records1 of 1
Warning letters and compliance actions
FDA Data Dashboard compliance actions
- Warning letterFormal notice of significant violationsCDER · DrugsFDA record
FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 1000627334, one row per refused product line.
6 refusals from 2019-07-18 to 2026-07-21 · charged DRUG GMPS on 6, UNAPPROVED on 2 · no FDA sample analysis
FDA firm profile- 2026-07-21
LIDOCAINE60QBA07
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports231-7818618-2/10002/4
- 2026-07-21
LIDOCAINE60QBA07
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports231-7818618-2/10002/3
- 2026-07-21
LIDOCAINE60QBA07
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports231-7818618-2/10002/2
- 2026-07-21
LIDOCAINE60QBA07
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
Division of Northern Border Imports231-7818618-2/10002/1
- 2024-01-31
BENZOCAINE (ANESTHETIC)60QAJ56
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-9241831-9/11/1
Show 1 more
- 2019-07-18
SUPPRESSANT N.E.C.66FBL99
DRUG GMPS 501(a)(2)(B), 801(a)(3); ADULTERATION
UNAPPROVED 505(a), 801(a)(3); UNAPPROVED NEW DRUG
Division of Southeast Imports799-1420247-6/11/1
Import alerts
FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.
- 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov
Date published 2011-01-18
- FDA’s entry
- Laboratoria Qualiphar NV · Rijksweg 9, Bornem, Antwerp BELGIUM
- FDA’s inspection record for FEI 1000627334
- Laboratoria Qualiphar NV · Rijksweg 9, Bornem, Belgium
Matched on exact firm name, street address and country. FDA printed no FEI on this entry.
9 products
- 55 - - - --Pharm Necess & Ctnr For Drug/Bio
- 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
- 60 - - - --Human and Animal Drugs
Show 6 more products
- 61 - - - --Human and Animal Drugs
- 62 - - - --Human and Animal Drugs
- 63 - - - --Human and Animal Drugs
- 64 - - - --Human and Animal Drugs
- 65 - - - --Human and Animal Drugs
- 66 - - - --Human and Animal Drugs
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000627334 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000627334. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.