Dairy Specialists L.L.C.
3309 Empire St, Evans, Colorado, United States
FEI 1000517712
FDA has 4 inspections on file for Dairy Specialists L.L.C. in Evans, Colorado (FEI 1000517712), from 2012 to 2015. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA published 2 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.
No warning letter, court action or import refusal is filed under this FEI.
Sources:FDA firm profile ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 4, 2012–2015
- 0 OAI · 3 VAI · 1 NAI
- Inspections with 483 observations shown
- 3 of 4
- Form 483s posted by FDA
- None held for this FEI
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Inspection history
4 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices2 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Quality control unit review of records
Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
Strict control not exercised over labeling issued
Strict control is not exercised over labeling issued for use in drug product labeling operations.
- NAINo objectionable conditions that need follow-upVeterinary · Monitoring of Marketed Animal Drugs, Feed, and DevicesNone
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance4 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Reprocessing procedures not written or followed
Procedures prescribing a system for reprocessing batches to insure that the reprocessed batches will conform with all established standards, specifications, and characteristics are not written.
Verification of component addition
Each component is not added to the batch by one person and verified by a second person..
Testing Each Component for Conformity with Specs
Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
Annual visual exams of drug products
Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
- VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Monitoring of Marketed Animal Drugs, Feed, and Devices6 citations published
FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.
Absence of Written Procedures
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Written procedures not established/followed
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Items to cover on annual reviews
Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
GMP Training Frequency
GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
Calibration - at intervals, written program, remedial action
The calibration of instruments is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
Show 1 more citation
Deviations from laboratory control requirements
Deviations from written test procedures are not recorded and justified.
Regulations FDA cited here
The 11 sections of 21 CFR in FDA’s published citations for 3 of this facility’s 4 inspections, with how many of them cited each.
- 21 CFR 211.25Personnel qualifications1 of 3
- 21 CFR 211.67Equipment cleaning and maintenance1 of 3
- 21 CFR 211.84Testing and approval or rejection of components, drug product containers, and closures1 of 3
- 21 CFR 211.100Written procedures; deviations1 of 3
- 21 CFR 211.101Charge-in of components1 of 3
- 21 CFR 211.115Reprocessing1 of 3
- 21 CFR 211.125Labeling issuance1 of 3
- 21 CFR 211.160General requirements1 of 3
Show all 11
- 21 CFR 211.170Reserve samples1 of 3
- 21 CFR 211.180General requirements1 of 3
- 21 CFR 211.192Production record review1 of 3
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 1000517712 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 1000517712. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.