Skip to content

Jaychem Industries Ltd

3 Kordel Place, East Tamaki, Auckland, New Zealand

FEI 1000492333

FDA has one inspection on file for Jaychem Industries Ltd in Auckland, New Zealand (FEI 1000492333). It ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CDER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 8 citations from this inspection, all under 21 CFR Part 211, the manufacturing rules for finished drugs. They are listed below.

FDA’s Import Alert 66-40 Red List names this firm at this address. FDA printed no FEI on the entry. No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
1, in 2014
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
None held for this FEI
Import refusals
None under this FEI
Import alerts
66-40Red List
Matched on FDA’s firm name and street address

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance8 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Component written specification

      Component testing is deficient in that each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.

    2. Written in-process control procedures

      Written procedures are not established that describe the in-process controls, tests, and examinations to be conducted on appropriate samples of in-process materials of each batch.

    3. Adequate number of batches on stability

      An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.

    4. Representative Samples

      Representative samples are not taken of each shipment of each lot of drug product containers for testing or examination.

    5. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    Show 3 more citations
    1. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

    2. Procedure Deviations Recorded and Justified

      Deviations from written production and process control procedures are not recorded and justified.

    3. Equipment Design, Size and Location

      Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.

Regulations FDA cited here

The 6 sections of 21 CFR in FDA’s published citations for this facility’s 1 inspection.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Import alerts

FDA import alert pages, last synced Nov 23, 2026, 04:17 UTC. On a Red List, FDA can detain the firm's listed products without examining them.

  • 66-40Red ListDetention Without Physical Examination of Drugs From Firms Which Have Not Met Drug GMPsImport alert pageAlert on fda.gov

    Date published 2014-12-22

    FDA’s entry
    Jaychem Industries Ltd · 3 Kordel Place, East Tamaki, Auckland, NEW ZEALAND
    FDA’s inspection record for FEI 1000492333
    Jaychem Industries Ltd · 3 Kordel Place, East Tamaki, Auckland, New Zealand

    Matched on exact firm name, street address and country. FDA printed no FEI on this entry.

    10 products

    • 55 - - - --Pharm Necess & Ctnr For Drug/Bio
    • 56 - - - --Antibiotics (Human/Animal)
    • 58 - - - --Human and Animal Therapeutic Biologic and Biosimilar Drugs
    Show 7 more products
    • 60 - - - --Human and Animal Drugs
    • 61 - - - --Human and Animal Drugs
    • 62 - - - --Human and Animal Drugs
    • 63 - - - --Human and Animal Drugs
    • 64 - - - --Human and Animal Drugs
    • 65 - - - --Human and Animal Drugs
    • 66 - - - --Human and Animal Drugs

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1000492333 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1000492333. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.