Skip to content

Aurora St. Luke's Medical Center

2900 W Oklahoma Ave, Milwaukee, Wisconsin, United States

FEI 1000389954

FDA has 9 inspections on file for Aurora St. Luke's Medical Center in Milwaukee, Wisconsin (FEI 1000389954), from 2008 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDA published one citation from this inspection, under 21 CFR Part 606, the manufacturing rules for blood and blood components. It is listed below. One FOIA request has asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 606.65(e) and 21 CFR 606.100(c).

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
9, 2008–2025
0 OAI · 6 VAI · 3 NAI
Inspections with 483 observations shown
4 of 9
Form 483s posted by FDA
↗
Requested under FOIA
1 request, latest Aug 28, 2025
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

9 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsPosted 483 · 1 citation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the distribution of blood and blood components for allogeneic transfusion were not always established.

  2. NAINo objectionable conditions that need follow-upBiologics · Vaccines and Allergenic ProductsNone
  3. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone
  4. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products1 citation published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Following manufacturer's instructions

      Failure to use supplies and reagents in a manner consistent with instructions provided by the manufacturer.

  5. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products7 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Following manufacturer's instructions

      Failure to use supplies and reagents in a manner consistent with instructions provided by the manufacturer.

    2. Procedures to maintain records of emergency transfusions

      Records including signature by the physician requesting the procedure are not maintained of all emergency transfusions .

    3. Required records

      Failure to maintain storage and distribution records.

    4. Equipment observed, standardized, calibrated

      Equipment used in the storage and distribution of blood and blood components is not observed on a regularly scheduled basis as prescribed in the SOP Manual.

    5. Thorough investigations

      Failure to perform a thorough investigation and make a record of the conclusions and follow-up of an unexplained discrepancy and a failure of a lot or unit to meet any of its specifications.

    Show 2 more citations
    1. Biological product deviation report

      Failure to submit a biological product deviation report within 45 days from the date you acquired information suggesting that a reportable event occurred.

    2. Concurrent documentation

      Records are not concurrently maintained with the performance of each significant step in the processing and distribution of each unit of blood and blood components so that all steps can be clearly traced.

  7. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood ProductsCitations not published
  8. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products3 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Following manufacturer's instructions

      Failure to use supplies and reagents in a manner consistent with instructions provided by the manufacturer.

    2. Management review - defined interval, sufficient frequency

      Management with executive responsibility has not reviewed the suitability and effectiveness of the quality system at defined intervals.

    3. Thorough investigations

      Failure to perform a thorough investigation and make a record of the conclusions and follow-up of a failure of a lot or unit to meet any of its specifications.

  9. NAINo objectionable conditions that need follow-upBiologics · Blood and Blood ProductsNone

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

One request to FDA under the Freedom of Information Act named this site, on Aug 28, 2025. It asked for a Form 483.

  • Inspection ending Jun 24, 2025VAI

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Aug 28, 2025FDA-FOIA-2025-10353Form 483· 1 of 5 sitesRecords released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.

Regulations FDA cited here

The 7 sections of 21 CFR in FDA’s published citations for 4 of this facility’s 9 inspections, with how many of them cited each.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1000389954 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1000389954. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.