Skip to content

General Organics

5805 S Oakley Ave, Chicago, Illinois, United States

FEI 1000305899

FDA has 2 inspections on file for General Organics in Chicago, Illinois (FEI 1000305899), from 2009 to 2010. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
2, 2009–2010
0 OAI · 1 VAI · 1 NAI
Inspections with 483 observations shown
1 of 2
Form 483s posted by FDA
None held for this FEI
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance14 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Adequate lab facilities not available

      Adequate lab facilities for testing and approval or rejection of components, drug product containers, closures, packaging materials, in-process materials, and drug products are not available to the quality control unit.

    2. Training--operations, GMPs, written procedures

      Employees are not given training in current good manufacturing practices and written procedures required by current good manufacturing practice regulations.

    3. Sanitation--buildings not clean, free of infestation

      Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

    4. Prepared for each batch, include complete information

      Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.

    5. Absence of Written Procedures

      There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

    Show 9 more citations
    1. Washing and toilet facilities are deficient

      Washing and toilet facilities lack soap or detergent, air driers or single-service towels, and cleanliness.

    2. Written procedures lacking for use of pesticides etc.

      Written procedures are lacking for the use of rodenticides, insecticides, fungicides, fumigating agents, and cleaning and sanitizing agents designed to prevent the contamination of equipment, components, drug product containers, closures, packaging, labeling materials, and drug products.

    3. Testing and release for distribution

      Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

    4. Annual visual exams of drug products

      Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.

    5. Procedures To Be in Writing

      Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval, and rejection of components, drug product containers, and closures.

    6. Reports of Analysis (Components)

      Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.

    7. Complaint Handling Procedure

      Procedures describing the handling of written and oral complaints related to drug products are not written or followed.

    8. Quarantine Storage of Components

      Incoming components and drug product containers are not stored under quarantine until they have been tested or examined, as appropriate, and released.

    9. Lot or control number assigned

      The drug product is not identified with a lot or control number that permits the determination of the history of the manufacture and control of the batch.

Regulations FDA cited here

The 13 sections of 21 CFR in FDA’s published citations for 1 of this facility’s 2 inspections.

Show all 13

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 1000305899 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 1000305899. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.