21 CFR 640.68: Processing
FDA's inspection data lists 4 Form 483 citations of 21 CFR 640.68 at 4 facilities, from July 2009 to December 9, 2025.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 4
- At 4 inspections
- Facilities cited
- 4
- Distinct FEIs
- Most recent citation
- Dec 9, 2025
- Biomat USA, Inc
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 640.68 from the Electronic Code of Federal Regulations.
§ 640.68 Processing.
(a) Sterile system. All administration and transfer sets inserted into blood containers used for processing Source Plasma intended for manufacturing into injectable or noninjectable products and all interior surfaces of plasma containers used for processing Source Plasma intended for manufacturing into injectable products shall be sterile, pyrogen-free, nontoxic, and compatible with the contents under normal conditions of use. Only Sodium Chloride Injection USP shall be used as a red blood cell diluent. If the method of separation of the plasma intended for injectable products involves a system in which an airway must be inserted into the plasma container, the airway shall be sterile and constructed so as to exclude microorganisms and maintain a sterile system.
(b) Final containers. Final containers used for Source Plasma, whether integrally attached or separated from the original blood container, shall not be entered prior to issuance for any purpose except for filling with the plasma. Such containers shall be uncolored and hermetically sealed, and shall permit clear visibility of the contents. Final containers and their components shall not interact with the plasma contents under conditions of storage and use so as to alter the safety, quality, purity, or potency of the plasma and shall provide adequate protection against external factors that may cause deterioration or contamination. Prior to filling, the final container shall be marked or identified by number or other symbol which will relate it directly to the donor.
(c) Preservative. Source Plasma shall not contain a preservative.
21 CFR Part 640: Additional Standards for Human Blood and Blood Products, Subpart GRead on eCFR
Citations by year
Form 483 citations of 21 CFR 640.68 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 1 in 2009
| Year | Form 483 citations |
|---|---|
| 2009 | 1 |
| 2012 | 1 |
| 2021 | 1 |
| 2025 | 1 |
How FDA words this citation
FDA's short descriptions and citation text on these 4 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Final container3 citations
- Separation1 citations
Citation text
- “Failure to ensure that where the method of separation of the plasma intended for injectable products involves a system in which an airway must be inserted into the plasma container, the airway is sterile.”1 citations
- “The final containers used for Source Plasma are not hermetically sealed and provide inadequate protection against external factors that may cause deterioration or contamination.”1 citations
- “The final containers used for Source Plasma are not identified prior to filling by number or other symbol which will relate them to the donors.”1 citations
- “The final containers used for Source Plasma provide inadequate protection against external factors that may cause deterioration or contamination.”1 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 640.68, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
Often cited at the same inspection
Of the 4 inspections where FDA cited 21 CFR 640.68, the share where it also cited each of these sections.
- 21 CFR 606.100Standard operating procedures3 (75%)
- 21 CFR 606.160Records3 (75%)
- 21 CFR 606.140Laboratory controls1 (25%)
- 21 CFR 606.20Personnel1 (25%)
- 21 CFR 606.60Equipment1 (25%)
- 21 CFR 606.65Supplies and reagents1 (25%)
Ask FDAgent about 21 CFR 640.68
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 640.68; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.