Skip to content

21 CFR 640.2: General requirements

FDA's inspection data lists 5 Form 483 citations of 21 CFR 640.2 at 4 facilities, from July 2010 to April 2, 2013.

Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.

Form 483 citations
5
At 5 inspections
Facilities cited
4
Distinct FEIs
Most recent citation
Apr 2, 2013
Department of Veterans Affairs Medical Center
Warning letters
0
State a violation of it

The regulation

The current text of 21 CFR 640.2 from the Electronic Code of Federal Regulations.

§ 640.2 General requirements.

(a) Manufacturing responsibility. All manufacturing of Whole Blood, including donor examination, blood collection, laboratory tests, labeling, storage and issue, shall be done under the supervision and control of the same licensed establishment except that the Director, Center for Biologics Evaluation and Research, may approve arrangements, upon joint request of two or more licensed establishments, which he finds are of such a nature as to assure compliance otherwise with the provisions of this subchapter.

(b) Blood container. The blood container shall not be entered prior to issue for any purpose except for blood collection or when the method of processing requires use of a different container. The container shall be uncolored and transparent to permit visual inspection of the contents and any closure shall be such as will maintain a hermetic seal and prevent contamination of the contents. The container material shall not interact with the contents under the customary conditions of storage and use, in such a manner as to have an adverse effect upon the safety, purity, or potency of the blood.

(c) Reissue of blood. Blood that has been removed from storage controlled by a licensed establishment shall not be reissued by a licensed establishment unless the following conditions are observed:

(1) The container has a tamper-proof seal when originally issued and this seal remains unbroken;

(2) A segment is properly attached and has not been removed, except that blood lacking a properly attached segment may be reissued in an emergency provided it is accompanied by instructions for sampling and for use within 6 hours after entering the container for sampling;

(3) The blood has been stored continuously at 1 to 6 °C and shipped between 1 and 10 °C;

(4) The blood is held for observation until a significant inspection consistent with the requirements of § 640.5(e) can be made.

21 CFR Part 640: Additional Standards for Human Blood and Blood Products, Subpart ARead on eCFR

Citations by year

Form 483 citations of 21 CFR 640.2 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).

Peak: 2 in 2012

Form 483 citations of 21 CFR 640.2 by inspection year
YearForm 483 citations
20101
20111
20122
20131

How FDA words this citation

FDA's short descriptions and citation text on these 5 citations, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.

Short descriptions

  • Blood not stored between 1-6 deg / shipped 1-10 deg5 citations

Citation text

  • “Reissued blood has not been stored continuously at 1 to 6 C.”3 citations
  • “Reissued blood has not been shipped between 1 and 10 C.”1 citations
  • “Reissued blood has not been stored continuously at 1 to 6 C and shipped between 1 and 10 C.”1 citations

Facilities cited most recently

The latest inspections where FDA cited 21 CFR 640.2, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.

Often cited at the same inspection

Of the 5 inspections where FDA cited 21 CFR 640.2, the share where it also cited each of these sections.

Ask FDAgent about 21 CFR 640.2

FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
  • Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
  • A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 640.2; FDAgent quotes that sentence exactly.
  • FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.