21 CFR 606.122: Circular of information
FDA's inspection data lists 1 Form 483 citation of 21 CFR 606.122 at 1 facility, from March 2010 to March 19, 2010.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 1
- At 1 inspection
- Facilities cited
- 1
- Distinct FEIs
- Most recent citation
- Mar 19, 2010
- Robley Rex VA Medical Center
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 606.122 from the Electronic Code of Federal Regulations.
§ 606.122 Circular of information.
A circular of information must be available for distribution if the product is intended for transfusion. The circular of information must provide adequate directions for use, including the following information:
(a) Instructions to mix the product before use.
(b) Instructions to use a filter in the administration equipment.
(c) The statement “Do Not Add Medications” or an explanation concerning allowable additives.
(d) A description of the product, its source, and preparation, including the name and proportion of the anticoagulant used in collecting the Whole Blood from each product is prepared.
(e) A statement that the product was prepared from blood that was found negative when tested for relevant transfusion-transmitted infections, as required under § 610.40 of this chapter (include each test that was performed).
(f) The statement: “Warning: The risk of transmitting infectious agents is present. Careful donor selection and available laboratory tests do not eliminate the hazard.”
(g) The names of cryoprotective agents and other additives that may still be present in the product.
(h) The names and results of all tests performed when necessary for safe and effective use.
(i) The use of the product, indications, contradications, side effects and hazards, dosage and administration recommendations.
(j) [Reserved]
(k) For Red Blood Cells, the circular of information must contain:
(1) Instructions to administer a suitable plasma volume expander if Red Blood Cells are substituted when Whole Blood is the indicated product.
(2) A warning not to add Lactated Ringer's Injection U.S.P. solution to Red Blood Cell products.
(l) For Platelets, the circular of information must contain:
(1) The approximate volume of plasma from which a sample unit of Platelets is prepared.
(2) Instructions to begin administration as soon as possible, but not more than 4 hours after entering the container.
(m) For Plasma, the circular of information must contain:
(1) A warning against further processing of the frozen product if there is evidence of breakage or thawing.
(2) Instructions to thaw the frozen product at a temperature appropriate for the product.
(3) When applicable, instructions to begin administration of the product within a specified time after thawing.
(4) Instructions to administer to ABO-group-compatible recipients.
(5) A statement that this product has the same risk of transmitting infectious agents as Whole Blood; other plasma volume expanders without this risk are available for treating hypovolemia.
(n) For Cryoprecipitated AHF, the circular of information must contain:
(1) A statement that the average potency is 80 or more International Units of antihemophilic factor.
(2) The statement: “Usually contains at least 150 milligrams of fibrinogen”; or, alternatively, the average fibrinogen level determined by assay of representative units.
(3) A warning against further processing of the product if there is evidence of breakage or thawing.
(4) Instructions to thaw the product for no more than 15 minutes at a temperature of between 30 and 37 °C.
(5) Instructions to store at room temperature after thawing and to begin administration as soon as possible but no more than 4 hours after entering the container or after pooling and within 6 hours after thawing.
(6) A statement that 0.9 percent Sodium Chloride Injection U.S.P. is the preferred diluent.
(7) Adequate instructions for pooling to ensure complete removal of all concentrated material from each container.
(8) The statement: “Good patient management requires monitoring treatment responses to Cryoprecipitated AHF transfusions with periodic plasma factor VIII or fibrinogen assays in hemophilia A and hypofibrinogenemic recipients, respectively.”
21 CFR Part 606: Current Good Manufacturing Practice for Blood and Blood Components, Subpart GRead on eCFR
Citations by year
Form 483 citations of 21 CFR 606.122 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 1 in 2010
| Year | Form 483 citations |
|---|---|
| 2010 | 1 |
How FDA words this citation
FDA's short descriptions and citation text on these 1 citation, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- Circular of information - required information1 citations
Citation text
- “Failure to provide an instruction circular for products intended for transfusion containing adequate directions for use and the information contained in 21 CFR 606.122.”1 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 606.122, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
Often cited at the same inspection
Of the 1 inspection where FDA cited 21 CFR 606.122, the share where it also cited each of these sections.
- 21 CFR 211.100Written procedures; deviations1 (100%)
- 21 CFR 211.22Responsibilities of quality control unit1 (100%)
- 21 CFR 606.171Reporting of product deviations by licensed manufacturers, unlicensed registered blood establishments, and transfusion services1 (100%)
- 21 CFR 606.40Facilities1 (100%)
Ask FDAgent about 21 CFR 606.122
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 606.122; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.