21 CFR 58.81: Standard operating procedures
FDA's inspection data lists 1 Form 483 citation of 21 CFR 58.81 at 1 facility, from July 2016 to July 8, 2016.
Counts: FDA Data Dashboard citations, last synced Nov 23, 2026, 04:25 UTC, and FDA's warning letters, last synced Nov 23, 2026, 04:17 UTC. Regulation text: eCFR. FDAgent is independent of FDA.
- Form 483 citations
- 1
- At 1 inspection
- Facilities cited
- 1
- Distinct FEIs
- Most recent citation
- Jul 8, 2016
- 4E Global, S.A.P.I. de C.V.
- Warning letters
- 0
- State a violation of it
The regulation
The current text of 21 CFR 58.81 from the Electronic Code of Federal Regulations.
§ 58.81 Standard operating procedures.
(a) A testing facility shall have standard operating procedures in writing setting forth nonclinical laboratory study methods that management is satisfied are adequate to insure the quality and integrity of the data generated in the course of a study. All deviations in a study from standard operating procedures shall be authorized by the study director and shall be documented in the raw data. Significant changes in established standard operating procedures shall be properly authorized in writing by management.
(b) Standard operating procedures shall be established for, but not limited to, the following:
(1) Animal room preparation.
(2) Animal care.
(3) Receipt, identification, storage, handling, mixing, and method of sampling of the test and control articles.
(4) Test system observations.
(5) Laboratory tests.
(6) Handling of animals found moribund or dead during study.
(7) Necropsy of animals or postmortem examination of animals.
(8) Collection and identification of specimens.
(9) Histopathology.
(10) Data handling, storage, and retrieval.
(11) Maintenance and calibration of equipment.
(12) Transfer, proper placement, and identification of animals.
(c) Each laboratory area shall have immediately available laboratory manuals and standard operating procedures relative to the laboratory procedures being performed. Published literature may be used as a supplement to standard operating procedures.
(d) A historical file of standard operating procedures, and all revisions thereof, including the dates of such revisions, shall be maintained.
21 CFR Part 58: Good Laboratory Practice for Nonclinical Laboratory Studies, Subpart ERead on eCFR
Citations by year
Form 483 citations of 21 CFR 58.81 by the year the inspection ended. FDA's citation data starts with inspections ending in October 2008, and the current year runs to the latest sync, so both are partial years (lighter bars).
Peak: 1 in 2016
| Year | Form 483 citations |
|---|---|
| 2016 | 1 |
How FDA words this citation
FDA's short descriptions and citation text on these 1 citation, most used first. These are FDA's standard summaries in its citation data, not the text of any one Form 483.
Short descriptions
- SOPs: availability1 citations
Citation text
- “Not all laboratory areas have immediately available laboratory manuals and standard operating procedures relative to the laboratory procedures being performed.”1 citations
Facilities cited most recently
The latest inspections where FDA cited 21 CFR 58.81, by inspection end date, with FDA's short description. Each links to the facility's FDA record on FDAgent.
Often cited at the same inspection
Of the 1 inspection where FDA cited 21 CFR 58.81, the share where it also cited each of these sections.
- 21 CFR 211.160General requirements1 (100%)
- 21 CFR 211.165Testing and release for distribution1 (100%)
- 21 CFR 211.166Stability testing1 (100%)
- 21 CFR 211.170Reserve samples1 (100%)
- 21 CFR 211.188Batch production and control records1 (100%)
- 21 CFR 211.194Laboratory records1 (100%)
Ask FDAgent about 21 CFR 58.81
FDAgent reads FDA's Form 483 citations, observations and warning letters and answers in plain English, with links to the records.
Related
About this data
- Citation counts come from FDA's Data Dashboard, which lists the regulation behind each Form 483 observation for inspections since October 2008.
- Observation excerpts come from Form 483 PDFs in FDA's electronic reading room, tied to this section only by exact wording as described above.
- A warning letter counts for this section when one of its numbered violation sentences cites 21 CFR 58.81; FDAgent quotes that sentence exactly.
- FDAgent rebuilds this page every week from FDA's public data and is independent of FDA.