Zhejiang Guobang Pharmaceutical Co., Ltd Form 483, March 2025
FDA issued this Form 483 to Zhejiang Guobang Pharmaceutical Co., Ltd in Shaoxing, China (FEI 3008617115) at the end of a drug inspection that ended March 3, 2025. It lists 1 observation. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Nov 13, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Mar 3, 2025
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Nov 13, 2026
- 620 days after the inspection
The 1 observation on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Unjustified water microbial testing controls
Laboratory controls lack scientifically justified and appropriate specifications and test procedures necessary to ensure that components meet established standards for identity, quality, and purity. Specifically, (b)(4) water is utilized in the critical cleaning of equipment in classified rooms during the water was also used as a component in the manufacturing processes of your drug substances. (b)(4) Batch manufacturing of drug substances including, but not limited to, (b)(4) released and shipped to the US market. A. USP compendial methods recognize that scientific standards for culturing (b)(4) Your firm has not justified that the (b)(4) mL sample of mL for (b)(4) sample sizes of up to (b)(4) (b)(4) sampling locations is appropriate to derive water currently tested for microbial monitoring of (b)(4) statistically valid colony counts at your site. Additionally, your firm has not validated that (b)(4) mL sample taken adequately captures all microbial colonies present in the larger (b)(4) mL sample collected at for (b)(4) water (b)(4) each (b)(4) B. Your firm has failed to detect and enumerate microorganisms that have been released by potential biofilms water system. Current within your (b)(4) water system to evaluate the overall state of control of the (b)(4) water system method validation studies do not include additional organisms typically isolated from the (b)(4) (house isolates) since your firm does not identify the normal microbiome. C. Your firm's (b)(4) water specification is not scientifically justified to exclude objectionable microorganisms from the (b)(4) water samples cultured during the tests for Total Aerobic Microbial Count (TAMC) and Total Viable Bacteria, Molds and Yeasts Count (TYMC). The microbial specifications for (b)(4) water include "Total Viable cfu/mL", "Total Bacteria, Molds and Yeasts Count <= (b)(4) cfu/mL", "Total Aerobic Microbial Count <= (b)(4) cfu/mL", and "Specified Microorganisms: Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus should be (b)(4) per (b)(4) mL of water sample". Your firm has failed to speciate recoveries found on TAMC and TYMC (b)(4) to determine if the specified objectionable microorganisms or other pathogenic bacteria are present in your (b)(4) water system below alert and action limits.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.