Zhejiang Guobang Pharmaceutical Co., Ltd
Hangzhou Gulf Shangyu Economic, No 6 Weiwu Road; And Technological Development Zone, Shaoxing, China
FEI 3008617115DUNS 545538183
FDA has 3 inspections on file for Zhejiang Guobang Pharmaceutical Co., Ltd in Shaoxing, China (FEI 3008617115), from 2015 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below. Three FOIA requests have asked FDA for this inspection's 483.
2 import refusals are filed under this FEI, the latest on . No warning letter or court action is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant is Zhejiang Guobang Pharmaceutical Co., Ltd. (D-U-N-S 545538183).
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 3, 2015–2025
- 0 OAI · 2 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 3
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 3 requests, latest Jul 2, 2026
- Warning letters
- None on file
- Import refusals
- 2 refusals
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Unjustified water microbial testing controls
Laboratory controls lack scientifically justified and appropriate specifications and test procedures necessary to ensure that components meet established standards for identity, quality, and purity. Specifically, (b)(4) water is utilized in the critical cleaning of equipment in classified rooms during the water was also used as a component in the manufacturing processes of your drug substances. (b)(4) Batch manufacturing of drug substances including, but not limited to, (b)(4) released and shipped to the US market. A. USP compendial methods recognize that scientific standards for culturing (b)(4) Your firm has not justified that the (b)(4) mL sample of mL for (b)(4) sample sizes of up to (b)(4) (b)(4) sampling locations is appropriate to derive water currently tested for microbial monitoring of (b)(4) statistically valid colony counts at your site. Additionally, your firm has not validated that (b)(4) mL sample taken adequately captures all microbial colonies present in the larger (b)(4) mL sample collected at for (b)(4) water (b)(4) each (b)(4) B. Your firm has failed to detect and enumerate microorganisms that have been released by potential biofilms water system. Current within your (b)(4) water system to evaluate the overall state of control of the (b)(4) water system method validation studies do not include additional organisms typically isolated from the (b)(4) (house isolates) since your firm does not identify the normal microbiome. C. Your firm's (b)(4) water specification is not scientifically justified to exclude objectionable microorganisms from the (b)(4) water samples cultured during the tests for Total Aerobic Microbial Count (TAMC) and Total Viable Bacteria, Molds and Yeasts Count (TYMC). The microbial specifications for (b)(4) water include "Total Viable cfu/mL", "Total Bacteria, Molds and Yeasts Count <= (b)(4) cfu/mL", "Total Aerobic Microbial Count <= (b)(4) cfu/mL", and "Specified Microorganisms: Escherichia coli, Pseudomonas aeruginosa and Staphylococcus aureus should be (b)(4) per (b)(4) mL of water sample". Your firm has failed to speciate recoveries found on TAMC and TYMC (b)(4) to determine if the specified objectionable microorganisms or other pathogenic bacteria are present in your (b)(4) water system below alert and action limits.
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
Three requests to FDA under the Freedom of Information Act named this site, most recently on Jul 2, 2026. Each one asked for a Form 483.
Inspection ending Mar 3, 2025VAI
3 requests. In the inspection history above. FDA has posted its Form 483.
- Jul 2, 2026FDA-FOIA-2026-6297Form 483Records released
- Sep 5, 2025FDA-FOIA-2025-10586Form 483· 1 of 2 sitesRecords released
- Jun 21, 2025FDA-FOIA-2025-7920Form 483· 1 of 10 sitesWithdrawn
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
Import refusals
FDA Data Dashboard, last synced Nov 23, 2026, 04:17 UTC. Shipments FDA refused entry into the US, filed under FEI 3008617115, one row per refused product line.
2 refusals from 2022-05-16 to 2024-02-16 · charged DIRSEXMPT on 2, FRNMFGREG on 1 · no FDA sample analysis
FDA firm profile- 2024-02-16
AZITHROMYCIN (MACAROLIDES)56ICR76
DIRSEXMPT 502(f)(1), 801(a)(3); MISBRANDING
Division of Northeast ImportsKL1-0276596-5/11/1
- 2022-05-16
CIPROFLOXACIN HYDROCHLORIDE (ANTI-BACTERIAL PART I) (NOT ANTIBIOTIC)61FCS55
DIRSEXMPT 502(f)(1), 801(a)(3); MISBRANDING
FRNMFGREG 502(o), 801(a)(3); MISBRANDING
Division of West Coast Imports065-0402209-3/11/1
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing
- Registration runs through
- Dec 31, 2027
- Registrant
- Zhejiang Guobang Pharmaceutical Co., Ltd.D-U-N-S 545538183
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. Every record here is filed under FEI 3008617115 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every record on this page is filed under FEI 3008617115. Records filed under another FEI or name, including other sites of the same company, are not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.