Maiva Pharma Private Limited Form 483, February 2026
FDA issued this Form 483 to Maiva Pharma Private Limited in India (FEI 3014362214) at the end of an inspection that ran from February 10 to February 20, 2026. It lists 3 observations.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Mar 6, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection
- Feb 10–20, 2026
- —
- FDA's outcome
- Not classified
- Not classified yet
- Posted by FDA
- Mar 6, 2026
- 14 days after the inspection
The 3 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate control of original production records
Production records do not contain complete information relating to the production and control of each batch. On February 10, 2026, during the initial walkthrough of your facility, numerous original CGMP documents associated with the manufacture of U.S. marketed drug products were observed discarded in trash bags located in the scrap area. These documents were not marked as copies, voided through an established procedure, or otherwise reconciled as part of an approved document control system. The discarded records included, but were not limited to: A. Discarded gloves containing handwritten Environmental Monitoring (EM) sampling details (settle plates exposure time) related to activities performed February 8, 2026, for gq Injection, Commercial Batch No. 4 B. In-process leak test equipment reports, including ge sample results, for US marketed product Li) USP ga mg/mL), Commercial Batch No. os, signed by Production and IPQA personnel on February 09, 2026, found torn into multiple pieces. C. Two (2) weighing verification printout of intact API bags prior to transfer into the aseptic area for US marketed product usr mg/mL), Commercial Batch No. generated February 9, 2026, using balance PROD/g5/G-016. D. A gw | sterilization fg "1 containing handwritten time entries documenting aseptic interventions times (e.g., forceps transfer, jy | transfer, fy sanitization, and forceps fixing) performed on February 8, 2026, US marketed" product [ Injection USP, Commercial Batch No. fey E. Ape fill volume weighing report for@vials generated ata on February 9, 2026, using balance PROD/MFG/4-007, for US marketed product Batch B® USP | mgmL), Commercial Batch No. F. Printed 5 measurement data recorded at 12:14 on February 9, 2026, for Line Bator the manufacturing of USP Units, Exhibit Batch No. which was strike-marked and discarded. Printout was found with value of gg which is below the batch manufacturing record established limit range of gy wl G. Four (4) dispensing weight balance printouts for issued raw materials and excipients for gg | FO USP Units, Exhibit Batch No. m@ generated February 7, 2026, using balances RMS/094 and RMS/007. H. Three (3) weight check print reports generated at ™"|(2) and 7 (1) on February 8, 2026, for be vessel PRODVFCHPO! used in the manufacture of [0 ®® USP Units, Exhibit Batch No. using balance PROD/MF Gye 010. In combination, these findings demonstrate a failure to maintain and control original manufacturing records. Currently, original raw data printouts generated in the manufacturing areas are not subject to adequate controls, reconciliation or retention, allowing for uncontrolled disposal of CGMP documentation with no Quality Unit oversight. Additionally, documentation of aseptic interventions (e.g., 0 setup and EM interventions) is not being documented contemporaneously, as required to maintain reliability and integrity of data.
- 2
Insufficient investigation of deviations/OOS
There is a failure to thoroughly review any unexplained discrepancy or the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. A. Your firm failed to ensure that aseptic processing activities are performed in accordance with established procedures and that deviations from approved practices are investigated. For example, during review of Deviation Investigation Report DV/001/25/035, initiated following a microbial excursion observed on February 28, 2025, a® CFU/Plate was recovered from the vial sealing LAF (Grade A) area, pq ID: ge Line ® Capping and Sealing zone during environmental monitoring associated with the manufacture of Injection, USP ma % (Batch No. ge As part of the investigation DV/001/25/035, a GEMBA walkthrough was conducted by your Quality Unit in the sealing area of Line ® on March 03, 2025, during the manufacture of =a @ 5 ®o® Injection @@ mg/mL, (No USA), Batch No. pq In this walkthrough, operators located in the Grade B area were observed performing RABS interventions during sealing operations in the Grade A area. During the same walkthrough, operators were also observed failing to perform required gq sanitization for periods exceeding ye while conducting aseptic interventions in the Grade A area. In addition, forceps used in the Grade A area were observed being introduced into the Grade B area and subsequently returned to the Grade A environment. Your firm does not have a written procedure that defines whether interventions in the sealing area are permitted or prohibited, nor does it define the conditions, controls, or limitations under which such interventions may be performed. Your Deputy General Manager stated that interventions can be performed in this area; however, these interventions are not limited in frequency, may be performed “N™ times during operations and are not documented in the commercial batch records. In addition, no LAF is installed above the® RABS yy | In where the intervention is performed to protect the Grade A conditions in the sealing area from the Grade B background conditions from where the employee performs the intervention. Furthermore, the) RABS 4 in the capping/sealing area are not equipped with alarms or any electronic monitoring system to detect, record, or trend events. Note that from the vial stoppering zone to the sealing and capping zone, the conveyor length is According to your Deputy General Manager in this location jy | interventions such as removal of broken and fallen vials might occur during aseptic filling operations. Moreover, your Quality Unit has not performed airflow visualization (smoke) studies under dynamic conditions to evaluate the impact of jy RABS) interventions and personnel manipulations on unidirectional airflow and protection of the Grade A critical zone. The absence of such studies does not provide assurance that unidirectional airflow is maintained during ge m@ interventions. In addition, your firm’s media fill studies did not simulate or evaluate the maximum number of i interventions that may be performed during routine production, nor did they represent worst-case conditions for interventions in this area. The deviations observed by your firm during the GEMBA walkthrough, including interventions, inadequateyq, Sanitization, and movement of tools between Grade A and Grade B areas, were not independently investigated or assessed. Instead, these inadequate aseptic practices were only referenced as possible contributing factors (Root Cause) for Deviation Investigation Report DV/001/25/035. Additionally, during the inspectional walkthrough conducted on February 13, 2026, of Filling Line ®® during filling operations ofp Injection ®@me® mL, (aseptic filling), (No-USA), Batch No. we observed an operator introducing directly from the Grade B area into the jy RABS Grade A (Sealing) area to perform a sensor adjustment intervention. It is unknow how this intervention is cl
Shortened here; the PDF has the full text.
- 3
Lack of aseptic and sterilization procedures
Your firm failed to establish and follow appropriate written procedures that are designed to prevent microbiological contamination of drug products purporting to be sterile, and that include validation of all aseptic and sterilization processes.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.