Skip to content

Maiva Pharma Private Limited

India

FEI 3014362214DUNS 725656438

FDA has 2 inspections on file for Maiva Pharma Private Limited in India (FEI 3014362214), from 2022 to 2026. The latest ended on ; FDA has not posted its classification yet.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. One of the eight FOIA requests for this site has asked FDA for this inspection's 483, and one more for the records from a later inspection, ending Jul 22, 2026, that FDA's Data Dashboard doesn't list yet.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for manufacturing, packing, labeling and analysis, through Dec 31, 2027. Its registrant is Maiva Pharma Private Limited (D-U-N-S 725656438).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
Inspections on file
2, 2022–2026
0 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
1 of 2
Form 483s posted by FDA
↗
Requested under FOIA
8 requests, latest Mar 4, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. Not classified yetClassification not posted yetPosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate control of original production records

      Production records do not contain complete information relating to the production and control of each batch. On February 10, 2026, during the initial walkthrough of your facility, numerous original CGMP documents associated with the manufacture of U.S. marketed drug products were observed discarded in trash bags located in the scrap area. These documents were not marked as copies, voided through an established procedure, or otherwise reconciled as part of an approved document control system. The discarded records included, but were not limited to: A. Discarded gloves containing handwritten Environmental Monitoring (EM) sampling details (settle plates exposure time) related to activities performed February 8, 2026, for gq Injection, Commercial Batch No. 4 B. In-process leak test equipment reports, including ge sample results, for US marketed product Li) USP ga mg/mL), Commercial Batch No. os, signed by Production and IPQA personnel on February 09, 2026, found torn into multiple pieces. C. Two (2) weighing verification printout of intact API bags prior to transfer into the aseptic area for US marketed product usr mg/mL), Commercial Batch No. generated February 9, 2026, using balance PROD/g5/G-016. D. A gw | sterilization fg "1 containing handwritten time entries documenting aseptic interventions times (e.g., forceps transfer, jy | transfer, fy sanitization, and forceps fixing) performed on February 8, 2026, US marketed" product [ Injection USP, Commercial Batch No. fey E. Ape fill volume weighing report for@vials generated ata on February 9, 2026, using balance PROD/MFG/4-007, for US marketed product Batch B® USP | mgmL), Commercial Batch No. F. Printed 5 measurement data recorded at 12:14 on February 9, 2026, for Line Bator the manufacturing of USP Units, Exhibit Batch No. which was strike-marked and discarded. Printout was found with value of gg which is below the batch manufacturing record established limit range of gy wl G. Four (4) dispensing weight balance printouts for issued raw materials and excipients for gg | FO USP Units, Exhibit Batch No. m@ generated February 7, 2026, using balances RMS/094 and RMS/007. H. Three (3) weight check print reports generated at ™"|(2) and 7 (1) on February 8, 2026, for be vessel PRODVFCHPO! used in the manufacture of [0 ®® USP Units, Exhibit Batch No. using balance PROD/MF Gye 010. In combination, these findings demonstrate a failure to maintain and control original manufacturing records. Currently, original raw data printouts generated in the manufacturing areas are not subject to adequate controls, reconciliation or retention, allowing for uncontrolled disposal of CGMP documentation with no Quality Unit oversight. Additionally, documentation of aseptic interventions (e.g., 0 setup and EM interventions) is not being documented contemporaneously, as required to maintain reliability and integrity of data.

    2. Observation 2

      Insufficient investigation of deviations/OOS

      There is a failure to thoroughly review any unexplained discrepancy or the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed. A. Your firm failed to ensure that aseptic processing activities are performed in accordance with established procedures and that deviations from approved practices are investigated. For example, during review of Deviation Investigation Report DV/001/25/035, initiated following a microbial excursion observed on February 28, 2025, a® CFU/Plate was recovered from the vial sealing LAF (Grade A) area, pq ID: ge Line ® Capping and Sealing zone during environmental monitoring associated with the manufacture of Injection, USP ma % (Batch No. ge As part of the investigation DV/001/25/035, a GEMBA walkthrough was conducted by your Quality Unit in the sealing area of Line ® on March 03, 2025, during the manufacture of =a @ 5 ®o® Injection @@ mg/mL, (No USA), Batch No. pq In this walkthrough, operators located in the Grade B area were observed performing RABS interventions during sealing operations in the Grade A area. During the same walkthrough, operators were also observed failing to perform required gq sanitization for periods exceeding ye while conducting aseptic interventions in the Grade A area. In addition, forceps used in the Grade A area were observed being introduced into the Grade B area and subsequently returned to the Grade A environment. Your firm does not have a written procedure that defines whether interventions in the sealing area are permitted or prohibited, nor does it define the conditions, controls, or limitations under which such interventions may be performed. Your Deputy General Manager stated that interventions can be performed in this area; however, these interventions are not limited in frequency, may be performed “N™ times during operations and are not documented in the commercial batch records. In addition, no LAF is installed above the® RABS yy | In where the intervention is performed to protect the Grade A conditions in the sealing area from the Grade B background conditions from where the employee performs the intervention. Furthermore, the) RABS 4 in the capping/sealing area are not equipped with alarms or any electronic monitoring system to detect, record, or trend events. Note that from the vial stoppering zone to the sealing and capping zone, the conveyor length is According to your Deputy General Manager in this location jy | interventions such as removal of broken and fallen vials might occur during aseptic filling operations. Moreover, your Quality Unit has not performed airflow visualization (smoke) studies under dynamic conditions to evaluate the impact of jy RABS) interventions and personnel manipulations on unidirectional airflow and protection of the Grade A critical zone. The absence of such studies does not provide assurance that unidirectional airflow is maintained during ge m@ interventions. In addition, your firm’s media fill studies did not simulate or evaluate the maximum number of i interventions that may be performed during routine production, nor did they represent worst-case conditions for interventions in this area. The deviations observed by your firm during the GEMBA walkthrough, including interventions, inadequateyq, Sanitization, and movement of tools between Grade A and Grade B areas, were not independently investigated or assessed. Instead, these inadequate aseptic practices were only referenced as possible contributing factors (Root Cause) for Deviation Investigation Report DV/001/25/035. Additionally, during the inspectional walkthrough conducted on February 13, 2026, of Filling Line ®® during filling operations ofp Injection ®@me® mL, (aseptic filling), (No-USA), Batch No. we observed an operator introducing directly from the Grade B area into the jy RABS Grade A (Sealing) area to perform a sensor adjustment intervention. It is unknow how this intervention is cl

      Shortened here; the PDF has the full text.

    Show observation 3
    1. Observation 3

      Lack of aseptic and sterilization procedures

      Your firm failed to establish and follow appropriate written procedures that are designed to prevent microbiological contamination of drug products purporting to be sterile, and that include validation of all aseptic and sterilization processes.

  2. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Eight requests to FDA under the Freedom of Information Act named this site, most recently on Mar 4, 2026.

  • Inspection ending Jul 22, 2026

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Feb 16, 2026FDA-FOIA-2026-1591EIRWithdrawn
  • Inspection ending Feb 20, 2026Not classified yet

    1 request. In the inspection history above. FDA has posted its Form 483.

    1. Feb 25, 2026FDA-FOIA-2026-1955Form 483Records released
  • Inspection ending Feb 10, 2026

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Mar 12, 2026. FDAgent holds no copy that FDA posted.

    1. Mar 4, 2026FDA-FOIA-2026-2211Form 483Records released
  • Inspection ending Nov 20, 2025

    1 request. Not listed in FDA’s Data Dashboard yet. None of FDA’s log entries for these requests say records were released.

    1. Nov 24, 2025FDA-FOIA-2025-13238Form 483No records found
  • Inspection ending Jul 21, 2025

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Oct 3, 2025. FDAgent holds no copy that FDA posted.

    1. Sep 22, 2025FDA-FOIA-2025-11162Form 483Records released
  • Inspection ending Oct 29, 2022VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Oct 8, 2024FDA-FOIA-2024-8892Form 483 + EIRClosed
  • Inspection date not given

    2 requests. FDA released records in answer to a request for its Form 483 on Nov 14, 2025. FDAgent holds no copy that FDA posted.

    1. Mar 2, 2026FDA-FOIA-2026-2121Form 483Records released
    2. Nov 10, 2025FDA-FOIA-2025-12778Form 483Records released

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

FDA drug establishment registration

FDA registration search
Registered operations
Manufacturing, packing, labeling, analysis
Registration runs through
Dec 31, 2027
Registrant
Maiva Pharma Private LimitedD-U-N-S 725656438

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3014362214 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3014362214. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.