Maitland Labs of Central Florida Form 483, June 2019
FDA issued this Form 483 to Maitland Labs of Central Florida in Orlando, Florida (FEI 3013854204) at the end of a drug inspection that ended June 17, 2019. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Mar 9, 2020. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jun 17, 2019
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- Mar 9, 2020
- 266 days after the inspection
FDA's 9 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
- FDCA 503B(a)(10)
Drug product label, outsourcer facility
The labels of your outsourcing facility's drug products are deficient.
- FDCA 503B(a)(10)
Container label, outsourcer facility
The container labels of your outsourcing facility's drug products are deficient.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process.
Testing and release for distribution
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Sterility/pyrogen-free testing
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Cleaning System
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Lack of written stability program
There is no written testing program designed to assess the stability characteristics of drug products.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3013854204, newest first.
- Form 483, February 2020Inspection ended Feb 28, 2020 · Posted Mar 9, 2020OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.