Inventive Infusion Solutions, LP Form 483, August 2018
FDA issued this Form 483 to Inventive Infusion Solutions, LP in San Antonio, Texas (FEI 3014498447) at the end of a drug inspection that ended August 31, 2018. It lists 8 observations. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Apr 30, 2019. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Aug 31, 2018
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Apr 30, 2019
- 242 days after the inspection
The 8 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
No biological indicators used
Biological indicators are not used properly to verify the adequacy of the sterilization cycle. Specifically, Your firm relies on (b)(4) when (b)(4) sterilizing pellet drug product such as Testosterone 75 mg in (b)(4). Your firm does not use biological indicators (BIs) to verify the adequacy of the (b)(4) sterilization cycle. You do not place BIs in the (b)(4) used to house the pellets. BIs are not processed or subjected to the same conditions as the pellets therefore there is no assurance that the (b)(4) cycle parameters utilized to sterilize the pellets are adequate.
- 2
No endotoxin testing performed
Endotoxin level is not tested on the finished drug products. Specifically, You have no assurance that the endotoxin level of your intrathecal drug products is safe, since you do not have any endotoxin data and your firm doesn't perform endotoxin testing for the finished product. These preparations are made using non-sterile starting material. Furthermore, there is no endotoxin testing data for your bulk drug substances.
- 3
Non-depyrogenated equipment used
Non-sterilized and Non-depyrogenated equipment was used in sterile drug production. Specifically, Your firm depyrogenated glassware and equipment inside the (b)(4) within the unclassified area. The (b)(4) is being used to store glassware and equipment that are purported to be depyrogenated. You indicated that the glassware and equipment can be stored inside the (b)(4) indefinitely until use. Your firm has not established the hold time for the purported to be depyrogenated glassware and equipment to ensure that they are pyrogen free before use. The glassware and equipment are used to weigh bulk drug substance powder and mix solution. For example, the following drug products are produced using glassware. 1. Hydroxyprogesterone Caproate 250mg/ml Injection 2. HCG 1,000U/ml Injection 3. LIPO B Injection
- 4
Inadequate media fill simulations
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, Your firm does not use the depyrogenated glassware and equipment during the media fills to simulate the aseptic production operations within your facility. The glassware is used by your firm to weigh out bulk drug substance for producing sterile drug products.
- 5
Personnel exposed facial skin
Personnel did not disinfect to prevent contamination. Specifically, On 8/22/2018 and 8/28/2018, operator (b)(4) was observed with exposed facial skin while cleaning the surfaces inside the ISO 5 area of (b)(4) Hood. The cleaning processes within the ISO 5 area are the same for the (b)(4) and (b)(4) operations of (b)(4).
- 6
Beta-lactam cross-contamination risk
You produced beta-lactam drugs without providing adequate containment, segregation, cleaning of work surfaces, cleaning of utensils and cleaning of personnel to prevent cross-contamination. Specifically, Your firm does not have a specific written process and procedure to describe the handling and cleaning of Beta lactam productions within the ISO 5 areas. Your firm does not document the cleaning and disinfectant solutions used after production to ensure that the work surfaces are cleaned adequately to reduce the potential of cross contamination of Beta-lactam such as Ceftazidime 25mg/ml ophthalmic solution and Ceftazidime 50mg/ml otic solution. The ISO 5 areas are shared between the Beta-lactam and other drug products.
- 7
Unsealed ceiling tiles in cleanroom
Unsealed, loose ceiling tiles were observed in your cleanroom. Specifically, On 08/24/2018, I observed visible gaps of approximately 0.5 cm between the HEPA filter grate panel and the ceiling panel frame and between the ceiling panel and the wall panel inside the ISO 7 clean room. These gaps are above the ISO 5 (b)(4) hood that is being used for aseptic processing/sterilization processes. The ISO 5 (b)(4) hood was observed being used by operator (b)(4) to produce HCG 1,000U/ml Injection lot # 08242018@10.
- 8
Non-sterile disinfectants used
Disinfecting agents used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, Your firm is using the non-sterile (b)(4) Disinfectant Solution to disinfect surfaces within the ISO 5 areas. For example, on 08/22/2018, I observed operator (b)(4) cleaning the two ISO 5 areas with (b)(4) Disinfectant Solution.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.