Skip to content

Inventive Infusion Solutions, LP

18866 Stone Oak Pkwy Ste 101a, San Antonio, Texas, United States

FEI 3014498447

FDA has one inspection on file for Inventive Infusion Solutions, LP in San Antonio, Texas (FEI 3014498447). It ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 8 observations from the PDF; they are listed below.

No warning letter, court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
1, in 2018
Inspections with 483 observations shown
1 of 1
Form 483s posted by FDA
↗
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

1 inspection · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 8 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      No biological indicators used

      Biological indicators are not used properly to verify the adequacy of the sterilization cycle. Specifically, Your firm relies on (b)(4) when (b)(4) sterilizing pellet drug product such as Testosterone 75 mg in (b)(4). Your firm does not use biological indicators (BIs) to verify the adequacy of the (b)(4) sterilization cycle. You do not place BIs in the (b)(4) used to house the pellets. BIs are not processed or subjected to the same conditions as the pellets therefore there is no assurance that the (b)(4) cycle parameters utilized to sterilize the pellets are adequate.

    2. Observation 2

      No endotoxin testing performed

      Endotoxin level is not tested on the finished drug products. Specifically, You have no assurance that the endotoxin level of your intrathecal drug products is safe, since you do not have any endotoxin data and your firm doesn't perform endotoxin testing for the finished product. These preparations are made using non-sterile starting material. Furthermore, there is no endotoxin testing data for your bulk drug substances.

    Show observations 3 to 8
    1. Observation 3

      Non-depyrogenated equipment used

      Non-sterilized and Non-depyrogenated equipment was used in sterile drug production. Specifically, Your firm depyrogenated glassware and equipment inside the (b)(4) within the unclassified area. The (b)(4) is being used to store glassware and equipment that are purported to be depyrogenated. You indicated that the glassware and equipment can be stored inside the (b)(4) indefinitely until use. Your firm has not established the hold time for the purported to be depyrogenated glassware and equipment to ensure that they are pyrogen free before use. The glassware and equipment are used to weigh bulk drug substance powder and mix solution. For example, the following drug products are produced using glassware. 1. Hydroxyprogesterone Caproate 250mg/ml Injection 2. HCG 1,000U/ml Injection 3. LIPO B Injection

    2. Observation 4

      Inadequate media fill simulations

      Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, Your firm does not use the depyrogenated glassware and equipment during the media fills to simulate the aseptic production operations within your facility. The glassware is used by your firm to weigh out bulk drug substance for producing sterile drug products.

    3. Observation 5

      Personnel exposed facial skin

      Personnel did not disinfect to prevent contamination. Specifically, On 8/22/2018 and 8/28/2018, operator (b)(4) was observed with exposed facial skin while cleaning the surfaces inside the ISO 5 area of (b)(4) Hood. The cleaning processes within the ISO 5 area are the same for the (b)(4) and (b)(4) operations of (b)(4).

    4. Observation 6

      Beta-lactam cross-contamination risk

      You produced beta-lactam drugs without providing adequate containment, segregation, cleaning of work surfaces, cleaning of utensils and cleaning of personnel to prevent cross-contamination. Specifically, Your firm does not have a specific written process and procedure to describe the handling and cleaning of Beta lactam productions within the ISO 5 areas. Your firm does not document the cleaning and disinfectant solutions used after production to ensure that the work surfaces are cleaned adequately to reduce the potential of cross contamination of Beta-lactam such as Ceftazidime 25mg/ml ophthalmic solution and Ceftazidime 50mg/ml otic solution. The ISO 5 areas are shared between the Beta-lactam and other drug products.

    5. Observation 7

      Unsealed ceiling tiles in cleanroom

      Unsealed, loose ceiling tiles were observed in your cleanroom. Specifically, On 08/24/2018, I observed visible gaps of approximately 0.5 cm between the HEPA filter grate panel and the ceiling panel frame and between the ceiling panel and the wall panel inside the ISO 7 clean room. These gaps are above the ISO 5 (b)(4) hood that is being used for aseptic processing/sterilization processes. The ISO 5 (b)(4) hood was observed being used by operator (b)(4) to produce HCG 1,000U/ml Injection lot # 08242018@10.

    6. Observation 8

      Non-sterile disinfectants used

      Disinfecting agents used in the ISO 5 classified aseptic processing areas were not sterile. Specifically, Your firm is using the non-sterile (b)(4) Disinfectant Solution to disinfect surfaces within the ISO 5 areas. For example, on 08/22/2018, I observed operator (b)(4) cleaning the two ISO 5 areas with (b)(4) Disinfectant Solution.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3014498447 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3014498447. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.