Skip to content

Infusion Partners, LLC Form 483, January 2018

FDA issued this Form 483 to Infusion Partners, LLC in Canfield, Ohio (FEI 3013995728) at the end of a drug inspection that ended January 26, 2018. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Jan 26, 2018
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
2,182 days after the inspection
Facility
FEI 3013995728
Canfield, Ohio

FDA's 10 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. FDCA 501(a)(2)(A)

    Beta-lactam drugs, inadequate sanitation

    You produced beta-lactam drugs without providing adequate containment and segregation to prevent cross-contamination.

  2. FDCA 501(a)(2)(A)

    Disinfectant contact time

    Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection.

  3. FDCA 501(a)(2)(A)

    Personnel habits, contamination

    Personnel did not disinfect and change gloves frequently enough to prevent contamination.

  4. FDCA 501(a)(2)(A)

    First pass air blockage, open unit with sterile product

    Personnel conducted aseptic manipulations and placed equipment/supplies in an area that blocked the movement of first pass air around an open unit, either before or after it was filled with sterile product.

  5. FDCA 501(a)(2)(A)

    Improper gowning, contamination

    Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated.

  6. FDCA 501(a)(2)(A)

    Disinfecting materials, aseptic processing area

    Materials or supplies were not disinfected prior to entering the aseptic processing areas.

  7. FDCA 501(a)(2)(A)

    Air flow quality, higher classified area

    Your facility design allowed the influx of poor quality air into a higher classified area.

  8. FDCA 501(a)(2)(A)

    Personnel contact outside ISO 5 area

    Personnel touched equipment or other surfaces located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing without changing or sanitizing gloves.

  9. FDCA 501(a)(2)(A)

    Disruption of airflow from personnel movement

    Personnel moved rapidly in the vicinity of open sterile units and instruments, which disrupted the airflow and increased the risk of bringing lesser quality air into the ISO 5 classified aseptic processing area.

  10. FDCA 501(a)(2)(A)

    Cleanliness, ISO-classified areas

    The ISO 5 classified aseptic processing areas had visibly dirty equipment or surface.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • Warning LetterMar 20, 2019CDER · 418 days after this inspection ended

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.