Skip to content

Infusion Partners, LLC

4137 Boardman Canfield Rd Ste Ll04, Canfield, Ohio, United States

FEI 3013995728

FDA has 2 inspections on file for Infusion Partners, LLC in Canfield, Ohio (FEI 3013995728), from 2018 to 2021. The latest ended on and was classified NAI, no action indicated.

NAI means FDA found no objectionable conditions or practices, or found none that justified further action.

The most recent OAI inspection ended on Jan 26, 2018. FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
NAI
Inspections on file
2, 2018–2021
1 OAI · 0 VAI · 1 NAI
Inspections with 483 observations shown
1 of 2
1 posted 483 not matched to an inspection
Form 483s posted by FDA
↗
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance10 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. FDCA 501(a)(2)(A)

      Beta-lactam drugs, inadequate sanitation

      You produced beta-lactam drugs without providing adequate containment and segregation to prevent cross-contamination.

    2. FDCA 501(a)(2)(A)

      Disinfectant contact time

      Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection.

    3. FDCA 501(a)(2)(A)

      Personnel habits, contamination

      Personnel did not disinfect and change gloves frequently enough to prevent contamination.

    4. FDCA 501(a)(2)(A)

      First pass air blockage, open unit with sterile product

      Personnel conducted aseptic manipulations and placed equipment/supplies in an area that blocked the movement of first pass air around an open unit, either before or after it was filled with sterile product.

    5. FDCA 501(a)(2)(A)

      Improper gowning, contamination

      Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated.

    Show 5 more citations
    1. FDCA 501(a)(2)(A)

      Disinfecting materials, aseptic processing area

      Materials or supplies were not disinfected prior to entering the aseptic processing areas.

    2. FDCA 501(a)(2)(A)

      Air flow quality, higher classified area

      Your facility design allowed the influx of poor quality air into a higher classified area.

    3. FDCA 501(a)(2)(A)

      Personnel contact outside ISO 5 area

      Personnel touched equipment or other surfaces located outside of the ISO 5 classified aseptic processing area with gloved hands and then engaged in aseptic processing without changing or sanitizing gloves.

    4. FDCA 501(a)(2)(A)

      Disruption of airflow from personnel movement

      Personnel moved rapidly in the vicinity of open sterile units and instruments, which disrupted the airflow and increased the risk of bringing lesser quality air into the ISO 5 classified aseptic processing area.

    5. FDCA 501(a)(2)(A)

      Cleanliness, ISO-classified areas

      The ISO 5 classified aseptic processing areas had visibly dirty equipment or surface.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3013995728 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3013995728. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.