Hubei JXBio Pharmaceutical Co., Ltd. Form 483, March 2025
FDA issued this Form 483 to Hubei JXBio Pharmaceutical Co., Ltd. in Xianning, China (FEI 3016784508) at the end of a drug inspection that ended March 14, 2025. It lists 1 observation. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Mar 3, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Mar 14, 2025
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Mar 3, 2026
- 354 days after the inspection
The 1 observation on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Inadequate OOS/deviation investigations
Deviations and Out-of-Specifications (OOS) are not clearly documented, explained, or investigated in production discrepancy reports. Specifically, A. An investigation for deviation PC-C005-24002 was initiated on 04-12-2024 for a test result that did not meet (b) (4) (b) (4) (b) (4) requirements for Batch Intermediate purity due to improper use of a balance during material weighing. The CAPA for replacement of all the electronic scales in the workshop with those having a printing function was not implemented using the established change control process. B. An investigation for deviation PC-C005A-24002 was initiated on 04-04-2024 for a single impurity test result (b) (4) (b) (4) (b) (4) that did not meet requirements during the of Batch (b) (4) The deviation was opened following the closing of OOS-C005A-24001 on 04-05-2024 but did not reference the OOS investigation and conclusion. C. An investigation for deviation PC-C007-2023-001 was initiated on 12-05-2023 for Batch (b) (4) that did not meet process requirements. The investigation report did not clearly document the (b) (4) discrepancy, explain the process used to determine the root cause of contaminated or document the (b) (4) change control for update of the specification and test method. In addition, the investigation did not (b) (4) extend to other batches that may have been affected by the contaminated D. An investigation for out-of-specification OOS-C005A-24002 was initiated for a related substance impurity (b) (4) (b) (4) OOS for Batch During the investigation an additional impurity related OOS was discovered, but the OOS was closed before the root cause and corrective actions and preventative actions (CAPA) for the second OOS were determined and documented. No additional OOS investigation was initiated for the second impurity OOS.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.