Skip to content

Hubei JXBio Pharmaceutical Co., Ltd.

Xian'An Economic, No. 9 Lvshan Road; Xianan District, Xianning, China

FEI 3016784508DUNS 544470717

FDA has 2 inspections on file for Hubei JXBio Pharmaceutical Co., Ltd. in Xianning, China (FEI 3016784508), from 2024 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its one observation from the PDF; it is listed below.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, through Dec 31, 2027. Its registrant is Hubei JXBio Pharmaceutical Co.,Ltd (D-U-N-S 544470717).

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
2, 2024–2025
0 OAI · 2 VAI · 0 NAI
Inspections with 483 observations shown
1 of 2
Form 483s posted by FDA
↗
Requested under FOIA
4 requests, latest Feb 24, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 1 observation

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate OOS/deviation investigations

      Deviations and Out-of-Specifications (OOS) are not clearly documented, explained, or investigated in production discrepancy reports. Specifically, A. An investigation for deviation PC-C005-24002 was initiated on 04-12-2024 for a test result that did not meet (b) (4) (b) (4) (b) (4) requirements for Batch Intermediate purity due to improper use of a balance during material weighing. The CAPA for replacement of all the electronic scales in the workshop with those having a printing function was not implemented using the established change control process. B. An investigation for deviation PC-C005A-24002 was initiated on 04-04-2024 for a single impurity test result (b) (4) (b) (4) (b) (4) that did not meet requirements during the of Batch (b) (4) The deviation was opened following the closing of OOS-C005A-24001 on 04-05-2024 but did not reference the OOS investigation and conclusion. C. An investigation for deviation PC-C007-2023-001 was initiated on 12-05-2023 for Batch (b) (4) that did not meet process requirements. The investigation report did not clearly document the (b) (4) discrepancy, explain the process used to determine the root cause of contaminated or document the (b) (4) change control for update of the specification and test method. In addition, the investigation did not (b) (4) extend to other batches that may have been affected by the contaminated D. An investigation for out-of-specification OOS-C005A-24002 was initiated for a related substance impurity (b) (4) (b) (4) OOS for Batch During the investigation an additional impurity related OOS was discovered, but the OOS was closed before the root cause and corrective actions and preventative actions (CAPA) for the second OOS were determined and documented. No additional OOS investigation was initiated for the second impurity OOS.

  2. VAIObjectionable conditions found; FDA took no regulatory actionVeterinary · Pre-Approval Eval. of Animal Drugs and Food AdditivesCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Four requests to FDA under the Freedom of Information Act named this site, most recently on Feb 24, 2026.

  • Inspection ending Jan 1, 2025

    1 request. Not listed in FDA’s Data Dashboard yet. FDA released records in answer to a request for its Form 483 on Feb 26, 2026. FDAgent holds no copy that FDA posted.

    1. Feb 24, 2026FDA-FOIA-2026-1900Form 483Records released
  • Inspection ending Aug 30, 2024VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Dec 6, 2024FDA-FOIA-2024-10747Form 483Closed
  • Inspection date not given

    2 requests. None of FDA’s log entries for these requests say records were released.

    1. Jun 23, 2025FDA-FOIA-2025-7931Form 483· 1 of 10 sitesWithdrawn
    2. Nov 20, 2024FDA-FOIA-2024-10261Inspection records· 1 of 3 sitesClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing
Registration runs through
Dec 31, 2027
Registrant
Hubei JXBio Pharmaceutical Co.,LtdD-U-N-S 544470717

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3016784508 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3016784508. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.