GE HealthCare Form 483, February 2025

FDA issued this Form 483 to GE HealthCare in Lindesnes, Norway (FEI 3002807778) at the end of a drug inspection that ended February 7, 2025. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Nov 17, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 7, 2025
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Nov 17, 2026
648 days after the inspection
Facility
FEI 3002807778
Lindesnes, Norway

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate endotoxin deviation investigations and CAPA

    Deviation investigations are not conducted thoroughly to identify root cause(s) and insufficient CAPA actions were implemented to prevent reoccurrences. Specifically, multiple deviation investigations were initiated for endotoxins detected in the API process intermediates, during the manufacturing of (b) (4) API (b) (4) Endotoxins were detected from multiple batches of API products manufactured between Feb 2022 to May-Sept 2024, initiating at least six (6) deviations. Each observed endotoxin event was investigated with deviation investigation, and CAPAs were identified or implemented. The investigations failed to identify the root cause(s) and source(s) of the observed endotoxins in the manufacturing process and implemented CAPA actions did not mitigate the endotoxin from the production process/equipment. CAPA actions identified from the investigation initiated for endotoxins detected on the latest (b) (4) API (b) (4) batches (May-Sept 2024), have not been implemented to date. Between Feb 2022 to Sept 2024, following deviation investigations were initiated for endotoxins detected during the manufacturing of (b) (4) API (b) (4) product/intermediates: • PR444720, initiated on 16Feb2022, impacting batch no. (b) (4) • DEV-03494 (PR471820), initiated on Sept 2023, impacting batch no. (b) (4) • DEV-03495 (PR472566), initiated on Oct 2023, impacting batch no. (b) (4) • DEV-07580 (PR475000), initiated on Nov 2023, impacting batch no. (b) (4) • DEV-10764 (PR478137), initiated on Feb 2024, impacting batch no. (b) (4) • DEV-13365, initiated for multiple batches: 02May2024 for batch: (b) (4) 21May24 for Batch# (b) (4); 04Jun24 for Batch# (b) (4); 20Aug24 for Batch# (b) (4); 10Sep24 for Batch# (b) (4)

  2. 2

    Inadequate contamination controls for API filling

    Lack of appropriate controls to prevent contaminations of manufactured drug substances. Specifically, A. The exhaust from the dust collector used during the API filling operations are not filtered adequately, and not vented outside the production area. The blower unit for the dusk collector is located in the common production area and does not have an external exhaust vent. Additionally, the air filtration system within the blower unit does not adequately capture drug particles from the filling operations and the drug particles are exhausted inside the common production area. The blower/filtration unit was observed with coating of (b) (4) particles, resembling drug substances, and visible (b) (4) particles were observed in the surrounding manufacturing area. The blower unit is equipped with general particle filter and not a HEPA filtration system. B. Manufactured product containers were not protected to prevent contamination and debris. The finished drug substance (API) containers staged for filling operations for (b) (4) [illegible] in Building (b) were observed without protective covers (4) There were no protective barriers over the open container tops, lined with (b) (4) bags, and the lined product containers were exposed to the room environment without any protection from falling debris or environmental contaminants. These open API product containers were observed in the filling room and the adjacent staging room and remained in this condition until the start of the filling operation (b) (4)

  3. 3

    Annual product reviews not per procedure timelines

    Annual product quality reviews were not conducted as per the written procedure. Specifically, annual Product Quality Review (PQR) reports were not issued and approved within the timelines specified in the written procedure, SOP# LIU 0463, "Annual Evaluation of Product", version 7.0. As per the written procedure, PQR reports are to be reviewed and approved by (b) (4) (b) (4) All four APR reports I reviewed were approved and made effective after the required approval date of (b) (4) and one of the PQR report (b) (4) (b) (4) PQR report) was not approved until (b) (4) after the required approval date. Additionally, there are no written requirements for the annual PQR reports to be approval by the top management for the site, and the Site Head did not sign/approve any of the four PQR reports I reviewed.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.