GE Healthcare AS, Lindesnes Site
Lindesnesveien 208, Lindesnes, Norway
FEI 3002807778DUNS 518890970
Company: GE Healthcare Inc. · Linked by exact D-U-N-S match (053046579) in FDA registration data
FDA has 2 inspections on file for GE Healthcare AS, Lindesnes Site in Lindesnes, Norway (FEI 3002807778), from 2017 to 2025. The latest ended on and was classified VAI, voluntary action indicated.
VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.
FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below.
No warning letter, court action or import refusal is filed under this FEI.
As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, packing and analysis, through Dec 31, 2027. Its registrant, GE Healthcare Inc. (D-U-N-S 053046579), has registered 4 other sites.
Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026
Ask FDAgent about this site
Email me when FDA posts a new inspection, Form 483 or warning letter for this site
Weekly, on a free account. Pause it any time.
Comparing suppliers? Check this site beside 2 others, free
- Latest inspection
- VAI
- Inspections on file
- 2, 2017–2025
- 0 OAI · 1 VAI · 1 NAI
- Inspections with 483 observations shown
- 1 of 2
- Form 483s posted by FDA
- ↗
- Requested under FOIA
- 1 request, latest Jul 12, 2026
- Warning letters
- None on file
- Import refusals
- None under this FEI
- Import alerts
- Not linked by FEI
- FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
- Drug establishment registration
- Through
Inspection history
2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC
- VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations
Read this Form 483 on its own page →Form 483 PDF on fda.gov
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.
- Observation 1
Inadequate endotoxin deviation investigations and CAPA
Deviation investigations are not conducted thoroughly to identify root cause(s) and insufficient CAPA actions were implemented to prevent reoccurrences. Specifically, multiple deviation investigations were initiated for endotoxins detected in the API process intermediates, during the manufacturing of (b) (4) API (b) (4) Endotoxins were detected from multiple batches of API products manufactured between Feb 2022 to May-Sept 2024, initiating at least six (6) deviations. Each observed endotoxin event was investigated with deviation investigation, and CAPAs were identified or implemented. The investigations failed to identify the root cause(s) and source(s) of the observed endotoxins in the manufacturing process and implemented CAPA actions did not mitigate the endotoxin from the production process/equipment. CAPA actions identified from the investigation initiated for endotoxins detected on the latest (b) (4) API (b) (4) batches (May-Sept 2024), have not been implemented to date. Between Feb 2022 to Sept 2024, following deviation investigations were initiated for endotoxins detected during the manufacturing of (b) (4) API (b) (4) product/intermediates: • PR444720, initiated on 16Feb2022, impacting batch no. (b) (4) • DEV-03494 (PR471820), initiated on Sept 2023, impacting batch no. (b) (4) • DEV-03495 (PR472566), initiated on Oct 2023, impacting batch no. (b) (4) • DEV-07580 (PR475000), initiated on Nov 2023, impacting batch no. (b) (4) • DEV-10764 (PR478137), initiated on Feb 2024, impacting batch no. (b) (4) • DEV-13365, initiated for multiple batches: 02May2024 for batch: (b) (4) 21May24 for Batch# (b) (4); 04Jun24 for Batch# (b) (4); 20Aug24 for Batch# (b) (4); 10Sep24 for Batch# (b) (4)
- Observation 2
Inadequate contamination controls for API filling
Lack of appropriate controls to prevent contaminations of manufactured drug substances. Specifically, A. The exhaust from the dust collector used during the API filling operations are not filtered adequately, and not vented outside the production area. The blower unit for the dusk collector is located in the common production area and does not have an external exhaust vent. Additionally, the air filtration system within the blower unit does not adequately capture drug particles from the filling operations and the drug particles are exhausted inside the common production area. The blower/filtration unit was observed with coating of (b) (4) particles, resembling drug substances, and visible (b) (4) particles were observed in the surrounding manufacturing area. The blower unit is equipped with general particle filter and not a HEPA filtration system. B. Manufactured product containers were not protected to prevent contamination and debris. The finished drug substance (API) containers staged for filling operations for (b) (4) [illegible] in Building (b) were observed without protective covers (4) There were no protective barriers over the open container tops, lined with (b) (4) bags, and the lined product containers were exposed to the room environment without any protection from falling debris or environmental contaminants. These open API product containers were observed in the filling room and the adjacent staging room and remained in this condition until the start of the filling operation (b) (4)
Show observation 3
- Observation 3
Annual product reviews not per procedure timelines
Annual product quality reviews were not conducted as per the written procedure. Specifically, annual Product Quality Review (PQR) reports were not issued and approved within the timelines specified in the written procedure, SOP# LIU 0463, "Annual Evaluation of Product", version 7.0. As per the written procedure, PQR reports are to be reviewed and approved by (b) (4) (b) (4) All four APR reports I reviewed were approved and made effective after the required approval date of (b) (4) and one of the PQR report (b) (4) (b) (4) PQR report) was not approved until (b) (4) after the required approval date. Additionally, there are no written requirements for the annual PQR reports to be approval by the top management for the site, and the Site Head did not sign/approve any of the four PQR reports I reviewed.
- NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
Requested under FOIA
FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC
One request to FDA under the Freedom of Information Act named this site, on Jul 12, 2026. It asked for a Form 483.
Inspection date not given
1 request. FDA released records in answer to a request for its Form 483 on Jul 30, 2026. FDAgent holds no copy that FDA posted.
- Jul 12, 2026FDA-FOIA-2026-6634Form 483· 1 of 4 sitesRecords released
A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out.
FDA drug establishment registration
FDA registration search- Registered operations
- API manufacturing, packing, analysis
- Registration runs through
- Dec 31, 2027
- Registrant
- GE Healthcare Inc.D-U-N-S 053046579
From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.
Other sites with the same registrant
FDA’s registration file names GE Healthcare Inc. (D-U-N-S 053046579) as the registrant for this site and the 4 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.
- GE Healthcare (Shanghai) Co Ltd.Shanghai, China · FEI 30052923846 inspections6latestOct 30, 2025VAINone on file
- GE Healthcare Inc. (Medi-Physics, Inc. dba GE Healthcare)Arlington Heights, Illinois · FEI 14173389 inspections9latestSep 19, 2025NAINone on file
- GE Healthcare ASOslo, Norway · FEI 30028077798 inspections8latestApr 23, 2024VAINone on file
- GE Healthcare Ireland LimitedCarrigtwohill, Ireland · FEI 30035799534 inspections4latestNov 5, 2021VAINone on file
Go further than this page
FDAgent researches FDA’s records and links every answer to its source.
About this data. This site’s records are filed under FEI 3002807778 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
- Every inspection and enforcement record on this page is filed under FEI 3002807778. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
- FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
- Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
- “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
- Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
- FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.