Fuji Yakuhin Co., Ltd. Form 483, November 2022
FDA issued this Form 483 to Fuji Yakuhin Co., Ltd. in Toyama, Japan (FEI 3008538640) at the end of a drug inspection that ended November 25, 2022. FDA classified the inspection Voluntary Action Indicated (VAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Mar 6, 2025. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Nov 25, 2022
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Mar 6, 2025
- 832 days after the inspection
FDA's 3 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
Calibration/Inspection/Checking not done
Routine calibration of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Active ingredient retained sample kept
A sample which is representative of each lot in each shipment of each active ingredient is not retained.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.