Exela Pharma Sciences LLC Form 483, July 2019
FDA issued this Form 483 to Exela Pharma Sciences LLC in Lenoir, North Carolina (FEI 3008563008) at the end of a drug inspection that ended July 18, 2019. FDA classified the inspection Voluntary Action Indicated (VAI) and issued the facility a warning letter on April 9, 2021.
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted Oct 18, 2019. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jul 18, 2019
- Drugs · Drug Quality Assurance
- FDA's outcome
- VAI
- Voluntary Action Indicated
- Posted by FDA
- Oct 18, 2019
- 92 days after the inspection
FDA's 7 citations from this inspection
FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.
Investigations of discrepancies, failures
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Validation lacking for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Environmental Monitoring System
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Cleaning / Sanitizing / Maintenance
Equipment and utensils are not maintained at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Prepared for each batch, include complete information
Batch production and control records do not include complete information relating to the production and control of each batch.
Containers & Closures Clean, Sterilized, Pyrogen-free
Drug product containers and closures were not sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.
Procedures for sterile drug products
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
After this inspection
FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.
- Warning LetterApr 9, 2021Exela Pharma Sciences LLC warning letter, April 9, 2021CDER · 631 days after this inspection ended
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3008563008, newest first.
- Form 483, November 2024Inspection ended Nov 15, 2024 · Posted Feb 14, 2025OAI
- Form 483, September 2017Inspection ended Sep 28, 2017 · Posted Dec 9, 2019VAI
- Form 483, December 2016FDA record date Dec 23, 2016 · Posted Jan 17, 2024
- Form 483, January 2016FDA record date Jan 23, 2016 · Posted Jan 17, 2024
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.