Skip to content

Downing Labs, LLC Form 483, October 2015

FDA issued this Form 483 to Downing Labs, LLC in Dallas, Texas (FEI 3010087152) at the end of a drug inspection that ended October 9, 2015. FDA classified the inspection Official Action Indicated (OAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Oct 9, 2015
Drugs · Drug Quality Assurance
FDA's outcome
OAI
Official Action Indicated
Posted by FDA
Jan 17, 2024
3,022 days after the inspection
Facility
FEI 3010087152
Dallas, Texas

FDA's 11 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Buildings of Suitable Size, Construction, Location

    Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.

  2. Investigations of discrepancies, failures

    There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.

  3. Sterility/pyrogen-free testing

    Each batch of drug product purporting to be pyrogen-free is not laboratory tested to determine conformance to such requirements.

  4. Absence of Written Procedures

    There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.

  5. Validation lacking for sterile drug products

    Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.

  6. Test methods

    The accuracy, sensitivity, specificity, and reproducibility of test methods have not been established.

  7. Lack of written stability program

    There is no written testing program designed to assess the stability characteristics of drug products.

  8. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.

  9. Cleaning System

    Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.

  10. Establishment of time limitations

    Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.

  11. Environmental Monitoring System

    Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.

After this inspection

FDA's compliance actions for this FEI dated after this inspection and before its next one. FDAgent links a letter when FDA's case number ties it to this facility.

  • InjunctionJan 8, 2016CDER · 91 days after this inspection ended

Other Form 483s FDA posted for this facility

Every Form 483 FDA posts under FEI 3010087152, newest first.

All inspections at this facility →

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.