Skip to content

Custom RX LLC, dba Custom RX Compounding Pharmacy Form 483, August 2014

FDA issued this Form 483 to Custom RX LLC, dba Custom RX Compounding Pharmacy in Minneapolis, Minnesota (FEI 3003316042) at the end of a drug inspection that ended August 28, 2014. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted Jan 17, 2024. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Aug 28, 2014
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
Jan 17, 2024
3,429 days after the inspection
Facility
FEI 3003316042
Minneapolis, Minnesota

FDA's 7 citations from this inspection

FDA's citation titles and text from its Data Dashboard. These are FDA's summaries, not the Form 483 itself. FDAgent hasn't verified a reading of this PDF, so the Form 483's own words are in the PDF only.

  1. Written in-process control procedures

    Written procedures are not established that describe the tests to be conducted on appropriate samples of in-process materials of each batch.

  2. Adequate number of batches on stability

    An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.

  3. Testing and release for distribution

    Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.

  4. Procedures for non-sterile drug products

    Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.

  5. Microbiological testing

    Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.

  6. Scientifically sound laboratory controls

    Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that components conform to appropriate standards of identity, strength, quality and purity.

  7. Sanitation--buildings not clean, free of infestation

    Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • FDAgent shows a Form 483’s own text only when its reading of that PDF passes every check.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.