CFP Acquisitions, Inc Form 483, January 2022
FDA issued this Form 483 to CFP Acquisitions, Inc in Tulsa, Oklahoma (FEI 3001576820) at the end of a drug inspection that ended January 18, 2022. It lists 5 observations. FDA classified the inspection Official Action Indicated (OAI).
A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.
Source: FDA's Electronic Reading Room, posted May 31, 2022. Form 483 PDF on fda.gov. FDAgent is independent of FDA.
- Inspection ended
- Jan 18, 2022
- Drugs · Drug Quality Assurance
- FDA's outcome
- OAI
- Official Action Indicated
- Posted by FDA
- May 31, 2022
- 133 days after the inspection
The 5 observations on this Form 483
Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.
- 1
Released product with low potency
Your firm released drug product in which the strength differs from that which it purports or is represented to possess. Specifically, 3rd party testing of Lot#09082021@1 of Methylcobalamin 5000mcg/mL Injectable made on September 8, 2021 found the potency to be 89.3%. The specifications for assay for this product are[(o)-(4) l Your firm did not reject the product and instead distributed the product to customers, increasing the dose to be administered. The Formula Worksheet for this lot does not document the exact number of vials that were filled. Based on the next lot made, approximately0C6) {4)7 and(b)<4 vials were filled. Your firm has dispensed the entire lot.
- 2
Poor cleanroom air return design
Your cleanrooms are outfitted with HEPA filters directly adjacent to the return vent in the ceiling. Specifically, your ISO7 Buffer Room and ISO8 Ante Room are not designed with low wall air returns or returns near the floor. The air returns are in the ceiling next to the high efficiency particulate arrestance (HEPA) filter. This design does not allow for proper circulation of air and prevents effective dilution of particle-laden air by HEPA filtered air.
- 3
Missing dynamic smoke studies
There is a lack of routine and rigorous certification of the ISO 5 area, including smoke studies performed under dynamic conditions. Specifically, your firm has not performed smoke studies in the ISO 5 Laminar Flow Hood (LFH) and ISO 7 Buffer Room under dynamic conditions that simulate actual working conditions since 2018.
- 4
Use of non-pharmaceutical ingredient
You used a non-pharmaceutical grade component in the formulation of a drug product. Specifically, your firm uses1(6) (4) adetoadjust the pHof several sterile drug products, including[(t>r (4) Furthermore, your firm did not list this ingredient on the Formula Worksheets when used. Lots that were- made and dis ensed/distributed include lot #s _"'-__.________________, ~ f (4) land[(6) (4) lo~(6) (4) !
- 5
Inadequate media fill practices
Media fills were not performed to closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, media fills performed by your firm with each of the operators that work in the ISO 5 area do not closely simulate actual production conditions and/or cover worst case or most challenging conditions for "batch filling" (non-ophthalmic sterile drug products). In routine production, your firm fills sterile drug products into 4 (1:5) (4) vials and batch sizes can be in excess of ~bll units. The media fill your firm performs has the operator fill in 4 Your firm does not include any media fills with(6) (4) Your firm has no documentation showing the incubation and final read results for the f:j vials that are a(b)(4 fill in a (6) (4) vial. Your firm only documents the incubation and read results for the R6J<.flvials that area l>f{4 fill in a (6) (4 vial. This is a repeat observation from the 3/3-13/15 and 6/25-07/11/2018 inspections.
Other Form 483s FDA posted for this facility
Every Form 483 FDA posts under FEI 3001576820, newest first.
- Form 483, July 2018Inspection ended Jul 11, 2018 · Posted Jan 17, 2024VAI
- Form 483, March 2015Inspection ended Mar 13, 2015 · Posted Jan 17, 2024OAI
Ask FDAgent about this Form 483
FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.
Related
About this data
- The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
- The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
- FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
- FDAgent is independent of FDA.