Skip to content

CFP Acquisitions Inc.

6136 E 51st St, Tulsa, Oklahoma, United States

FEI 3001576820

FDA has 3 inspections on file for CFP Acquisitions Inc. in Tulsa, Oklahoma (FEI 3001576820), from 2015 to 2022. The latest ended on and was classified OAI, official action indicated.

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA posted the Form 483 from that inspection. FDAgent read its 5 observations from the PDF; they are listed below.

FDA issued a warning letter on (CDER). No court action or import refusal is filed under this FEI.

Sources:FDA firm profile ↗Form 483 PDF ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
3, 2015–2022
2 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
3 of 3
2 posted 483s not matched to an inspection
Form 483s posted by FDA
↗
3 posted
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

3 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC · FDA reading room, last synced Nov 23, 2026, 04:33 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality AssurancePosted 483 · 5 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Released product with low potency

      Your firm released drug product in which the strength differs from that which it purports or is represented to possess. Specifically, 3rd party testing of Lot#09082021@1 of Methylcobalamin 5000mcg/mL Injectable made on September 8, 2021 found the potency to be 89.3%. The specifications for assay for this product are[(o)-(4) l Your firm did not reject the product and instead distributed the product to customers, increasing the dose to be administered. The Formula Worksheet for this lot does not document the exact number of vials that were filled. Based on the next lot made, approximately0C6) {4)7 and(b)<4 vials were filled. Your firm has dispensed the entire lot.

    2. Observation 2

      Poor cleanroom air return design

      Your cleanrooms are outfitted with HEPA filters directly adjacent to the return vent in the ceiling. Specifically, your ISO7 Buffer Room and ISO8 Ante Room are not designed with low wall air returns or returns near the floor. The air returns are in the ceiling next to the high efficiency particulate arrestance (HEPA) filter. This design does not allow for proper circulation of air and prevents effective dilution of particle-laden air by HEPA filtered air.

    Show observations 3 to 5
    1. Observation 3

      Missing dynamic smoke studies

      There is a lack of routine and rigorous certification of the ISO 5 area, including smoke studies performed under dynamic conditions. Specifically, your firm has not performed smoke studies in the ISO 5 Laminar Flow Hood (LFH) and ISO 7 Buffer Room under dynamic conditions that simulate actual working conditions since 2018.

    2. Observation 4

      Use of non-pharmaceutical ingredient

      You used a non-pharmaceutical grade component in the formulation of a drug product. Specifically, your firm uses1(6) (4) adetoadjust the pHof several sterile drug products, including[(t>r (4) Furthermore, your firm did not list this ingredient on the Formula Worksheets when used. Lots that were- made and dis ensed/distributed include lot #s _"'-__.________________, ~ f (4) land[(6) (4) lo~(6) (4) !

    3. Observation 5

      Inadequate media fill practices

      Media fills were not performed to closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, media fills performed by your firm with each of the operators that work in the ISO 5 area do not closely simulate actual production conditions and/or cover worst case or most challenging conditions for "batch filling" (non-ophthalmic sterile drug products). In routine production, your firm fills sterile drug products into 4 (1:5) (4) vials and batch sizes can be in excess of ~bll units. The media fill your firm performs has the operator fill in 4 Your firm does not include any media fills with(6) (4) Your firm has no documentation showing the incubation and final read results for the f:j vials that are a(b)(4 fill in a (6) (4) vial. Your firm only documents the incubation and read results for the R6J<.flvials that area l>f{4 fill in a (6) (4 vial. This is a repeat observation from the 3/3-13/15 and 6/25-07/11/2018 inspections.

  2. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  3. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality Assurance6 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Personnel with exposed skin/glove issues

      Personnel engaged in aseptic processing were observed with exposed skin around the face and with their face and exposed skin inside of the ISO 5 hood. Personnel did not disinfect gloves to prevent contamination. Specifically, a) On 6/26/18 and 6/27/18, I observed your technician preparing sterile drug preparations in an ISO 5 laminar flow hood with exposed skin around the face (forehead, eyes and side of cheeks). b) On 6/26/18 and 6/27/18, I noted that your technician did not sanitize the second pair of sterile gloves after donning. Lot#06262018@1ofTri-Mix 15/0.Smg/Smcg/mL was made on 6/26/18. Lot #s 06272018@5 of Papaverine/Phentolamine30/lmg/mL, #06272018@6 of Tri-Mix 18/1110, and #06272018@7 of Tri-Mix 30/l/10 were made on 6/27/18.

    2. Observation 2

      Inadequate media fill simulation

      Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations. Specifically, media fills performed by your firm with each of the operators that work in the ISO 5 area do not closely simulate actual production conditions or cover worst case or most challenging conditions. In routine production, batch sizes can be in excess of l6Jl4l units and can involve [(b)(4)]. The media fill your firm performs has the operator [(b)(4)]. This same step is then repeated [(b)(4)] more times using [(b)(4)] each time. This is a repeat observation from the 3/3-13/15 inspection.

    Show observations 3 to 6
    1. Observation 3

      Insufficient disinfectant contact time

      Disinfectant contact time (also known as "dwell time") and coverage of the item being disinfected were insufficient to achieve adequate levels of disinfection. Specifically, your firm did not have adequate contact time for the [(b)(4) C'(b)(4) ] solution) or the [(b)(4)] for use as a sporicidal. Your technician sprays the solution onto a sterile wipe and then wipes down the surface of the ISO 5 hood, amounting to a contact time (surface being wet) of less than [illegible].

    2. Observation 4

      Inadequate environmental monitoring

      Environmental monitoring samples were not performed to ensure recovery of organisms. Specifically, on 7/2/18, I observed your technician wipe the surface of the ISO 5 laminar flow hood with sterile [(b)(4)] [illegible] minutes, she performed a surface sample of the site and after less than [illegible].

    3. Observation 5

      Unmonitored/erroneous pressure differentials

      Pressure differentials between areas with different air classifications were not monitored prior or during sterile drug production. Specifically, the magnahelic gauges that monitor the pressure differential between the ISO 7 cleanroom (room with ISO 5 laminar flow hoods) and the ISO 8 Ante Room (room where drug products are prepared) and the ISO 8 Ante Room and the unclassified pharmacy area, do not appear to be functioning properly, which may allow influx of poor quality air into a higher classified area. When the door from the unclassified pharmacy to the ISO 8 Ante Room is opened, both gauges show movement. When the door from the ISO 7 cleanroom to the ISO 8 Ante Room is opened, neither gauge moves.

    4. Observation 6

      Difficult-to-clean/particle-generating surfaces

      The ISO 5 classified aseptic processing area has difficult to clean or particle-generating equipment or surfaces. Specifically, the (b)(4) hood (ISO 5) located in your ISO 7 Cleanroom, has a cabinet that it is "mounted on a work surface constructed of pressed wood laminated with a [(b)(4)]."

  4. Not classified yetFDA posted this Form 483; FDAgent has not matched it to a Data Dashboard inspectionNo inspection matchedForm 483 pagePDF
  5. OAISignificant objectionable conditions; FDA recommended regulatory actionDrugs · Drug Quality Assurance9 citations published

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate personnel gowning

      Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform. Specifically, the general gowning attire for personnel working in the ISO 5/ISO 7 classified areas consists of the following: scrubs donned in the facility, two disposable lab coats (one worn from the sterile prep area (ISO 8 ante room) and the second worn over the first lab coat when entering the ISO 7 Cleanroom); a single hair net; a surgical face mask with ties; and dedicated shoes worn in ISO 8 and ISO 7 areas. All are non-sterile. The operators also use a single pair of non-sterile gloves donned in the sterile prep area and then don a single pair of sterile gloves under the ISO 5 hood. The general gowning requirements leave exposed skin around the eyes, forehead and neck of the person preparing the drug product. On 3/9/15, we watched the preparation of lot #03092015@22 of Hydromorphone 20mg/mL PF IT 20mg/mL Injectable, lot #03092015@8 of Morphine Sulfate 3 (PF) Injectable and lot #03092015 3 of Tri-Mix 18/ · in Hood

    2. Observation 2

      Inadequate environmental monitoring

      Aseptic processing areas are deficient regarding the system for monitoring environmental conditions. Specifically, a) Your firm does not perform environmental monitoring of the ISO 5 area every day that your firm is preparing sterile drug products. SOP 3.020 Environmental Monitoring of the Clean Room Facility, version 1.0 effective 10/10/14, states "microbial surface sampling in the class 100-100,000 work area will be performed [illegible]. [illegible] testing will be done." Your firm does not document the media type and lot number used to perform the environmental monitoring. b) Viable air monitoring of the ISO 7 cleanroom and the ISO 8 anteroom (sterile prep room) is only performed [illegible] during certification of the rooms. Your firm does not perform viable air monitoring in the ISO 5 laminar flow hoods. c) Your firm is not monitoring each operator working in the ISO 5 area and ISO 7 cleanroom. Your firm is currently sampling the fingertips of operators once every [illegible].

    Show observations 3 to 10
    1. Observation 3

      Sterilization process not validated

      Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include validation of the sterilization process. Specifically, a) Your firm has not validated the sterilization process for any of the drug products you prepare. Your firm prepares various drug products from bulk non-sterile active pharmaceutical ingredients (API) and excipients that are then either (b) (4) (b) (4) • · The drug products that Acetonide 40mg/mL Injectable, Testosterone Cypionate 200mg/mL Injectable and Estradiol/Testosterone 12.5/125mg pellet. Your firm has no documentation of the qualification of the (b)(4) for the drug products were (b) (4) developed. SOP 8.020, version 1.0 effective 10/10/14, requires that [illegible]. Your firm is not b) Media fills performed by your firm with each of the operators that work in the ISO 5 area do not closely simulate actual production conditions or cover worst case or most challenging conditions. In routine production, your firm fills various size vials (2 mL-30 mL vials) as well as syringes, and batch sizes can be in excess [illegible] units. The media fill your firm has the fill in [illegible].

    2. Observation 4

      Inadequate cleaning/disinfection practices

      Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions. Specifically, a) Your firm uses non-sterile wipes to disinfect the [illegible] ISO 5 laminar flow hoods where drug products are prepared. b) Your firm uses [illegible] brand to clean the floors and walls of the ISO 7 cleanroom where the ISO 5 laminar flow hoods are located. Your firm has no documentation or data to demonstrate that these mop heads are made for use in a cleanroom and are sterile and non shedding. c) Your firm uses an (b) (4) solution for cleaning/disinfecting the floors and walls in the ISO 7 cleanroom. Your firm does not have documentation to demonstrate that the product is effective in cleaning/disinfecting the room and no documentation to show the product is stable for the time it is used after preparation. d) Your firm does not use a sporicidal disinfectant in the ISO 5 laminar flow hoods and ISO 7 cleanroom where drug products are prepared.

    3. Observation 5

      Inadequate HEPA/pressure monitoring

      Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure. Specifically, a) The documentation from your 3rd party vendor for the certification of the [illegible] ISO 5 laminar flow hoods, the ISO 7 cleanroom and the ISO 8 ante room (sterile prep room) is deficient in that the last report, dated 9/11/14, does not include the following: i) Testing of the HEPA filter in the ISO 7 cleanroom. ii) Measurement of pressure in the cleanroom or ante room. iii) Measurement of the pressure differential between the cleanroom and the ante room and between the ante room and the general pharmacy area (unclassified area). iv) Measurement of the particle size to verify that the rooms and laminar flow hoods meet the requirements of an ISO 5, 7 or 8 area as stated in the report. b) There is no documentation of the actual pressure differential measurement between the ISO 7 cleanroom and the ISO 8 ante room (sterile prep room) and between the ISO 8 ante room (sterile prep room) and the unclassified general pharmacy during operations. The documentation of the daily check of the pressure differential only documents "pass" or "fail" for the reading. c) On 3/9/15, I observed the pressure gauge measuring the pressure differential between the ISO 8 ante room (sterile prep room) and the unclassified general pharmacy was at zero (0). When the door from the ante room to the general pharmacy was opened on 3/9/15, I observed the needle on the pressure gauge fall below zero (0). Several products were made in the rooms on 3/9/15, including lot #03092015@22 of Hydromorphone 20mg/mL PF IT 20mg/mL Injectable, lot #03092015@8 of Morphine Sulfate 30mg/mL (PF) Injectable and lot #03092015@33 of Tri-Mix 18/1mg/40mcg/mL Injectable.

    4. Observation 6

      No written cleaning/maintenance procedures

      Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product. Specifically, your firm cleans glass beakers and other utensils such as spatulas and scoops used to process drug products prior to sterilization, with brand household dish detergent and then in [illegible]. The water supplied to the equipment is [illegible]. Your firm has not [illegible] process to demonstrate [illegible] residue or cross contamination of drug substances or cleaning products occurs.

    5. Observation 7

      No routine sterility/endotoxin testing

      Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements. Specifically, your firm does not conduct routine sterility or endotoxin testing for all injectable drug (b) (4) 1' 1' (b) (4) products produced. Your current procedure is to test lots [illegible].

    6. Observation 8

      No stability testing/BUD justification

      There is no written testing program designed to assess the stability characteristics of drug products. Specifically, your firm does not have a written stability testing program to determine Beyond Use Dates (BUD) placed on all your drug products. For example, a) Your firm has no documentation to justify the following BUDs placed on these injectable drug products prepared by your firm. i. BUD of 180 days on Methylcobalamin 5000 mcg/mL Injectable. This product is preservative free and not labeled as a single dose vial. ii. BUD of 60 days on the Chorionic Gonadotropin (HCG) 1000 U/mL Injectable. iii. BUD of 180 days on Triamcinolone Acetonide 40 mg/mL Injectable. b) Your firm provided documentation of four (4) months of potency testing over time of Tri-Mix 30/2 mg/20 mcg/mL Injectable. However, there is no documentation of sterility or endotoxin testing performed for this product as part of this study. Your firm places a 180-day BUD on this product.

    7. Observation 10

      Equipment calibration program deficient

      Routine calibration of electronic equipment is not performed according to a written program designed to assure proper performance. Specifically, a) Your firm does not calibrate temperature measuring devices used to monitor the following: i) (b) (4) used to depyrogenate glass beakers used in the preparation of drug products; ii) The [illegible] used to [illegible] drug products; iii) [illegible] used to store finished sterile drug products; iv) Refrigerator used to store refrigerated active pharmaceutical ingredients (API) and finished drug products; v) "Supply Refrigerator" used to store media used for environmental monitoring; vi) Incubators used to incubate environmental monitoring samples, personnel monitoring samples and media fill vials. b) Your firm does not calibrate the pressure gauges used to monitor the measurement of the pressure differential between the ISO 7 cleanroom and the ISO 8 ante room and between the ISO 8 ante room and the unclassified general pharmacy. c) Your firm does not use certified standard weights to calibrate the Balance in the sterile prep room (ante room). This balance is used to weigh APIs and excipients used in the preparation of sterile drug products.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

  • Warning letterFormal notice of significant violationsCDER · DrugsFDA record

FDAgent links a letter’s text only when FDA’s compliance case number ties it to this FEI. No posted letter matched this one, so the link opens FDA’s record of the action.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3001576820 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3001576820. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.