Ajinomoto Company Inc. Form 483, February 2025

FDA issued this Form 483 to Ajinomoto Company Inc. in Kawasaki-City, Japan (FEI 3002806336) at the end of a drug inspection that ended February 21, 2025. It lists 3 observations. FDA classified the inspection Voluntary Action Indicated (VAI).

A Form 483 lists the investigators' observations at the end of an inspection. It is not FDA's final determination.

Source: FDA's Electronic Reading Room, posted May 6, 2026. Form 483 PDF on fda.gov. FDAgent is independent of FDA.

Inspection ended
Feb 21, 2025
Drugs · Drug Quality Assurance
FDA's outcome
VAI
Voluntary Action Indicated
Posted by FDA
May 6, 2026
439 days after the inspection
Facility
FEI 3002806336
Kawasaki-City, Japan

The 3 observations on this Form 483

Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent's.

  1. 1

    Inadequate root cause investigations

    Five out of five investigations into production deviations and laboratory out-of-specification results reviewed did not identify the true root cause and supported action to be taken to prevent a reoccurrence of the issue. For example: a. Deviation investigation DEV_KW_2024-073 was opened on 10/18/24 due to a lower than normal yield of [illegible] during of (b)(4) lot. The investigation found that the [illegible] for the tank was incorrectly wired, causing the [illegible] to [illegible] and the failure was attributed to this. On investigation, the miswiring was found to be due to a request from the Engineering department to the contractor providing the maintenance of the [illegible] which occurred without being entered in the change control system and without proper oversight. The investigation identified the wiring as the root cause and a correction was implemented to change the wiring; however, the investigation does not discuss the unreported change or what actions should be taken to correct and prevent a reoccurrence of the issue. b. Deviation investigation DEV_KW_2024-075 was opened on 10/22/24 due to a lower than normal yield of [illegible] during of 1 lot (the subsequent batch to the batch in deviation investigation DEV_KW_2024-073). The investigation found that the issues identified in deviation investigation DEV_KW_2024-073 were not responsible for the abnormal yield, and that the actual cause of the issue was due to a difference in design between the [illegible] and the [illegible]. The investigation attributed the issue to the different design of the [illegible] and a correction was implemented to clean the [illegible] off the [illegible] to allow the process to continue properly; however, the investigation does not discuss why the difference in design was not addressed during design qualification of the AEI or in the change control that was intended to prevent this issue, nor does it discuss what actions should be taken to correct and prevent a reoccurrence of the issue. c. Deviation investigation DEV_KW_2024-020 was opened on 4/17/24 to investigate an unusually low yield during the [illegible] step of lot [illegible]. The investigation found that the low yield was caused by the [illegible] solution and while the employee responsible for [illegible] was busy supervising a process. The investigation included a reassessment of the instructions and additional instruction as to what to do in similar situation, as well as an assessment of automating the process; however, there was no discussion of why the SOP did not correctly include all operations needed for the job and whether or not any changes need to be made to prevent a reoccurrence of the issue. d. Deviation investigation DEV_KW_2024-063 was opened on 8/19/24 due to a missed balance inspection after a power breaker was reset. The SOP required a calibration of the balance after power is restored, but the employees did not record a calibration after power was restored. The investigation determined that the record in use was not sufficient to allow the employees to properly and reliably record a check and the form was revised; however, there is no discussion of why the form was not designed correctly originally and whether or not any changes need to be made to prevent a reoccurrence of the issue. e. Out-of-specification investigation OOS_KW_2024-001 was opened on 2/16/24 due to an out-of-specification result for unknown impurity during related substances testing of lot [illegible]. The investigation found that the out-of-specification result was caused by improper cleaning of the balances and balance areas during sample weighing, which caused sample contamination. The investigation attributed the improper cleaning to inadequate instructions on cleaning in the SOP and included a correction to add more detail to ensure proper cleaning; however, the investigation does not discuss why the SOP was issued with inadequate instructions and whether or not any changes need to

    Shortened here; the PDF has the full text.

  2. 2

    No control for sample worksheet issuance

    The laboratory sample preparation worksheets used for preparation of all samples in the laboratory do not have a system to control and record issuance of the worksheets or to identify issuance of multiple worksheets for the same sample preparation. (b)

  3. 3

    No data on tank material compatibility

    There is no data to support that the [illegible] used in the construction of production tanks, including the (b)(4) Tank, L Tank, (b)(4) Storage Tanks, and the (b)(4) Tank, used to produce all APIs manufactured at the site is not additive to the APIs.

Ask FDAgent about this Form 483

FDAgent reads the 483, the facility's inspections, warning letters and FDA's citations and answers in plain English, with links to the records.

Edit it or ask as written. 3 questions free, no card needed.

About this data

  • The PDF and its dates come from FDA's Electronic Reading Room, last synced Nov 23, 2026, 04:33 UTC; the inspection, its outcome and FDA's citations from FDA's Data Dashboard.
  • The observations are the text FDAgent read from this PDF by OCR, shown only when every printed observation passed FDAgent’s checks against the scanned text.
  • FDAgent leaves out the names of the people the Form 483 is addressed to and of the investigators.
  • FDAgent is independent of FDA.