Skip to content

Ajinomoto Company Inc.

Kawasaki Plant, 1-1 Suzuki-Cho, Kawasaki-Ku, Kawasaki-City, Japan

FEI 3002806336DUNS 695028225

Company: Ajinomoto Health & Nutrition North America, Inc. · Linked by exact D-U-N-S match (099816548) in FDA registration data

FDA has 6 inspections on file for Ajinomoto Company Inc. in Kawasaki-City, Japan (FEI 3002806336), from 2009 to 2025. The latest ended on and was classified VAI, voluntary action indicated.

VAI means FDA investigators found objectionable conditions or practices, but FDA was not prepared to take or recommend regulatory action. The firm is expected to correct them voluntarily.

FDA posted the Form 483 from that inspection. FDAgent read its 3 observations from the PDF; they are listed below. Six of the eight FOIA requests for this site have asked FDA for this inspection's 483.

No warning letter, court action or import refusal is filed under this FEI.

As of Nov 21, 2026, the site is registered with FDA as a drug establishment for API manufacturing, labeling, analysis and relabeling, through Dec 31, 2027. Its registrant, Ajinomoto Health & Nutrition North America, Inc. (D-U-N-S 099816548), has registered 8 other sites.

Sources:FDA firm profile ↗Form 483 PDF ↗FDA drug establishment registrations ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
VAI
Inspections on file
6, 2009–2025
0 OAI · 3 VAI · 3 NAI
Inspections with 483 observations shown
1 of 6
Form 483s posted by FDA
↗
Requested under FOIA
8 requests, latest May 1, 2026
Warning letters
None on file
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗
Drug establishment registration
Through

Inspection history

6 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssurancePosted 483 · 3 observations

    Read this Form 483 on its own page →Form 483 PDF on fda.gov

    Read from the FDA-posted Form 483 PDF by OCR. FDAgent keeps an observation only when it matches the scanned text; check the PDF before quoting. The short titles are FDAgent’s.

    1. Observation 1

      Inadequate root cause investigations

      Five out of five investigations into production deviations and laboratory out-of-specification results reviewed did not identify the true root cause and supported action to be taken to prevent a reoccurrence of the issue. For example: a. Deviation investigation DEV_KW_2024-073 was opened on 10/18/24 due to a lower than normal yield of [illegible] during of (b)(4) lot. The investigation found that the [illegible] for the tank was incorrectly wired, causing the [illegible] to [illegible] and the failure was attributed to this. On investigation, the miswiring was found to be due to a request from the Engineering department to the contractor providing the maintenance of the [illegible] which occurred without being entered in the change control system and without proper oversight. The investigation identified the wiring as the root cause and a correction was implemented to change the wiring; however, the investigation does not discuss the unreported change or what actions should be taken to correct and prevent a reoccurrence of the issue. b. Deviation investigation DEV_KW_2024-075 was opened on 10/22/24 due to a lower than normal yield of [illegible] during of 1 lot (the subsequent batch to the batch in deviation investigation DEV_KW_2024-073). The investigation found that the issues identified in deviation investigation DEV_KW_2024-073 were not responsible for the abnormal yield, and that the actual cause of the issue was due to a difference in design between the [illegible] and the [illegible]. The investigation attributed the issue to the different design of the [illegible] and a correction was implemented to clean the [illegible] off the [illegible] to allow the process to continue properly; however, the investigation does not discuss why the difference in design was not addressed during design qualification of the AEI or in the change control that was intended to prevent this issue, nor does it discuss what actions should be taken to correct and prevent a reoccurrence of the issue. c. Deviation investigation DEV_KW_2024-020 was opened on 4/17/24 to investigate an unusually low yield during the [illegible] step of lot [illegible]. The investigation found that the low yield was caused by the [illegible] solution and while the employee responsible for [illegible] was busy supervising a process. The investigation included a reassessment of the instructions and additional instruction as to what to do in similar situation, as well as an assessment of automating the process; however, there was no discussion of why the SOP did not correctly include all operations needed for the job and whether or not any changes need to be made to prevent a reoccurrence of the issue. d. Deviation investigation DEV_KW_2024-063 was opened on 8/19/24 due to a missed balance inspection after a power breaker was reset. The SOP required a calibration of the balance after power is restored, but the employees did not record a calibration after power was restored. The investigation determined that the record in use was not sufficient to allow the employees to properly and reliably record a check and the form was revised; however, there is no discussion of why the form was not designed correctly originally and whether or not any changes need to be made to prevent a reoccurrence of the issue. e. Out-of-specification investigation OOS_KW_2024-001 was opened on 2/16/24 due to an out-of-specification result for unknown impurity during related substances testing of lot [illegible]. The investigation found that the out-of-specification result was caused by improper cleaning of the balances and balance areas during sample weighing, which caused sample contamination. The investigation attributed the improper cleaning to inadequate instructions on cleaning in the SOP and included a correction to add more detail to ensure proper cleaning; however, the investigation does not discuss why the SOP was issued with inadequate instructions and whether or not any changes need to

      Shortened here; the PDF has the full text.

    2. Observation 2

      No control for sample worksheet issuance

      The laboratory sample preparation worksheets used for preparation of all samples in the laboratory do not have a system to control and record issuance of the worksheets or to identify issuance of multiple worksheets for the same sample preparation. (b)

    Show observation 3
    1. Observation 3

      No data on tank material compatibility

      There is no data to support that the [illegible] used in the construction of production tanks, including the (b)(4) Tank, L Tank, (b)(4) Storage Tanks, and the (b)(4) Tank, used to produce all APIs manufactured at the site is not additive to the APIs.

  2. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  3. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  4. NAINo objectionable conditions that need follow-upDrugs · Drug Quality AssuranceNone
  5. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published
  6. VAIObjectionable conditions found; FDA took no regulatory actionDrugs · Drug Quality AssuranceCitations not published

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Eight requests to FDA under the Freedom of Information Act named this site, most recently on May 1, 2026.

  • Inspection ending Feb 21, 2025VAI

    6 requests. In the inspection history above. FDA has posted its Form 483.

    1. May 1, 2026FDA-FOIA-2026-4317Form 483Records released
    2. Jul 30, 2025FDA-FOIA-2025-9250Form 483 + EIRRecords released
    3. Jun 20, 2025FDA-FOIA-2025-7864Form 483· 1 of 10 sitesRecords released
    4. Jun 17, 2025FDA-FOIA-2025-7806Form 483· 1 of 3 sitesRecords released
    5. May 23, 2025FDA-FOIA-2025-4671Form 483· 1 of 3 sitesWithdrawn
    6. Apr 30, 2025FDA-FOIA-2025-3940Form 483Withdrawn
  • Inspection date not given

    2 requests. FDA released records in answer to a request for its Form 483 on Sep 15, 2025. FDAgent holds no copy that FDA posted.

    1. Mar 20, 2025FDA-FOIA-2025-2603Form 483Records released
    2. Apr 5, 2022FDA-FOIA-2022-2535EIRClosed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

FDA drug establishment registration

FDA registration search
Registered operations
API manufacturing, labeling, analysis, relabeling
Registration runs through
Dec 31, 2027
Registrant
Ajinomoto Health & Nutrition North America, Inc.D-U-N-S 099816548

From FDA’s Drug Establishments Current Registration Site, as of Nov 21, 2026. A registration says what a site told FDA it does. It is not an inspection result. FDA’s registration search looks firms up by name.

Other sites with the same registrant

FDA’s registration file names Ajinomoto Health & Nutrition North America, Inc. (D-U-N-S 099816548) as the registrant for this site and the 8 others below. That exact D-U-N-S number is the only link. A registrant is the firm that filed the registration, which is not always the owner.

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. This site’s records are filed under FEI 3002806336 in FDA’s data; other sites under its registrant are listed in summary only. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every inspection and enforcement record on this page is filed under FEI 3002806336. Other sites filed under the same registrant D-U-N-S are listed in summary only. Records filed under another FEI or name are otherwise not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.