Skip to content

Hemarus LLC

1295 Nw 40th Ave Ste 201, Lauderhill, Florida, United States

FEI 3019769008

FDA has 2 inspections on file for Hemarus LLC in Lauderhill, Florida (FEI 3019769008), from 2022 to 2024. The latest ended on and was classified OAI, official action indicated. FDA issued a warning letter on (CBER).

OAI means FDA found significant objectionable conditions and recommended regulatory or administrative action. It is the most serious of FDA's three inspection outcomes.

FDA published 11 citations from this inspection. They are listed below. Three of the four FOIA requests for this site have asked FDA for this inspection's 483.

No court action or import refusal is filed under this FEI.

Two regulations were cited at more than one inspection: 21 CFR 606.170(a) and 21 CFR 606.40(a)(1).

Sources:FDA firm profile ↗Warning letter ↗Synced Nov 23, 2026

Ask FDAgent about this site

Free account: 3 questions, no card needed. Each answer links to its FDA sources.

Email me when FDA posts a new inspection, Form 483 or warning letter for this site

Weekly, on a free account. Pause it any time.

Watch this facility

Comparing suppliers? Check this site beside 2 others, free

Latest inspection
OAI
Inspections on file
2, 2022–2024
1 OAI · 1 VAI · 0 NAI
Inspections with 483 observations shown
2 of 2
Form 483s posted by FDA
None held for this FEI
Requested under FOIA
4 requests, latest May 28, 2025
Import refusals
None under this FEI
Import alerts
Not linked by FEI
FDA lists import alert firms by name and address, rarely by FEI. Check FDA’s import alert list ↗

Inspection history

2 inspections · FDA Data Dashboard, last synced Nov 23, 2026, 04:25 UTC

  1. OAISignificant objectionable conditions; FDA recommended regulatory actionBiologics · Blood and Blood Products11 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Name, address, unique facility identifier

      The container label fails to include the license number of each manufacturer, for a licensed product.

    2. Concurrent documentation

      Records are not concurrently maintained with the performance of each significant step in the processing of each unit of blood and blood components so that all steps can be clearly traced.

    3. Qualifications of responsible personnel

      The personnel responsible for the collection, processing, storage and distribution of blood or blood components are not adequate in training and experience, including professional training as necessary to assure competent performance of their assigned functions, and to ensure that the final product has the safety, purity, potency, identity and effectiveness it purports or is represented to possess.

    4. Improper delegation of activities - SP & plasmapheresis

      The responsible physician improperly delegated donor eligibility activities related to the collection of Source Plasma.

    5. Adverse Reaction - Investigations

      A thorough investigation of each reported adverse reaction was not made.

    Show 6 more citations
    1. Responsible physician not on site

      The responsible physician was not present at the collection site when activities related to the collection of blood and blood components were delegated to a trained person who was not adequately trained and experienced in the performance of the activities.

    2. Biological product deviation report

      Failure to submit a biological product deviation report.

    3. Retention period

      Failure to retain records for 10 years after the records of processing have been completed.

    4. Establish, maintain and follow manufacturing SOPs

      Written standard operating procedures including all steps to be followed in the collection, processing, storage and distribution of blood and blood components for further manufacturing purposes were not always followed.

    5. Determination of lot numbers and supplies

      Appropriate records are not available to determine the lot numbers of supplies used for specific units of the final product.

    6. Provide space for examination

      Failure to provide adequate space for private examinations of individuals to determine their eligibility as blood donors.

  2. VAIObjectionable conditions found; FDA took no regulatory actionBiologics · Blood and Blood Products2 citations published

    FDA’s citation titles and text from its Data Dashboard. These are FDA’s summaries, not the Form 483 itself.

    1. Adverse Reaction - Investigations

      A thorough investigation of each reported adverse reaction was not made.

    2. Provide space for examination

      Failure to provide adequate space for examinations of individuals to determine their eligibility as blood donors.

Requested under FOIA

FDA FOIA logs, last synced Nov 23, 2026, 04:25 UTC

Four requests to FDA under the Freedom of Information Act named this site, most recently on May 28, 2025. Each one asked for a Form 483.

  • Inspection ending Apr 30, 2024OAI

    3 requests. In the inspection history above. FDA released records in answer to a request for its Form 483 on Jul 17, 2025. FDAgent holds no copy that FDA posted.

    1. May 28, 2025FDA-FOIA-2025-7079Form 483Records released
    2. Oct 17, 2024FDA-FOIA-2024-9189Form 483Closed
    3. Jul 24, 2024FDA-FOIA-2024-6517Form 483· 1 of 5 sitesClosed
  • Inspection ending Nov 4, 2022VAI

    1 request. In the inspection history above. None of FDA’s log entries for these requests say records were released.

    1. Nov 22, 2023FDA-FOIA-2023-10513Form 483Closed

A request is listed when it names this site’s FEI number or one of its FDA inspection IDs, or, after review, its exact street address. Requester names are left out. “Closed” means FDA’s log gives no further reason.

Regulations FDA cited here

The 8 sections of 21 CFR in FDA’s published citations for this facility’s 2 inspections, with how many of them cited each.

Warning letters and compliance actions

FDA Data Dashboard compliance actions

Go further than this page

FDAgent researches FDA’s records and links every answer to its source.

Free account: 3 questions, no card needed.

About this data. Every record here is filed under FEI 3019769008 in FDA’s data. FDAgent is independent of FDA, and FDA’s firm profile is the authoritative record.
  • Every record on this page is filed under FEI 3019769008. Records filed under another FEI or name, including other sites of the same company, are not shown here.
  • FDA posts only some Form 483s. A missing 483 does not mean no observations were issued, and classifications can change after FDA review.
  • Recalls are not shown, because FDAgent does not hold them by FEI. Import alerts are shown when FDA printed this FEI beside the firm on the alert, or when a Red List entry’s firm name, street address and country equal an inspection record under this FEI and no other FEI has that name. FDA lists most firms by name and address alone, so a site can be on an import alert without it appearing here.
  • “Last synced” is when FDAgent last copied that FDA source. FDA often publishes a record weeks after the inspection or action it describes.
  • Observation text comes from OCR of the scanned PDF. FDAgent keeps an observation only when it matches the scanned text, and marks unreadable spans [illegible]. Last synced Nov 23, 2026, 04:30 UTC.
  • FDAgent is independent and not affiliated with FDA. Check the FDA firm profile for the authoritative record.